Abstract: the frame shear wall structure of the business building has a large space, and the advantages of flexible layout, and was widely used to design, in actual design work, appear some difficulties, such as elevator well stair concentrated set of shear wall regional position and reverse irregular; Architectural appearance is beautiful; The structural displacement control; Shear wall decorate not uniform; Even the beam concentrated too which stress etc analysis, this article through engineering examples of elaborate computation, adjust the design idea optimizing design scheme, expounds the design problem.

Keywords: top; The frame shear wall; Structure; Design calculation

中图分类号:[TU208.3]文献标识码:A 文章编号:

1.工程概况

1.1本工程为地上14 层地下一层建筑。工程位于上海,建筑用途为办公,展览,商业等,建筑屋面结构高度46.2m,底层层高4.5m,标准层3m。地上地下总建筑面积1.8万m2。标准层活载展厅功能取为3.5kN/m2,办公楼取值2.0 kN/m2,机房取7.0 kN/m2。考虑隔墙自由布置特点,活载增加每延米墙重/3 的数值。

1.2考虑大空间及结构高度的需要,结构抗力体系为框架剪力墙结构。2、3 层结构平面如图1,标准层结构平面如图2。由图可见,因甲方建筑外观的要求,建筑北侧及东侧墙面因安装玻璃幕墙及建筑效果缘故,不允许设置剪力墙,只能在西部南部及楼梯间布置剪力墙以控制位移。但楼电梯间布置也较偏,这样造成了结构质心和刚心不重合,造成了扭转不规则。但从平面规则性和竖向布置规则性角度看,结构均属于较为规则,无开大洞大凹进也并无明显竖向刚度突变。

图1 2、3 层结构平面图图2 标准层结构布置图

1.3主要设计条件计算参数如下:结构安全等级为丙类,抗震设防烈度7度,地震加速度为0.10g。……