摘要:遮热板本身不带走任何热量也不起热,在两辐射表面间加设一块遮热板就可以增加其隔热热阻,从而减少它们之间的辐射换热,可知遮热板有辐射隔热的作用。本文通过介绍遮热板的运用,进一步分析了遮热板的工作原理并得出相关结论希望可以给各读者带来启发。
关键词:遮热罩(板);隔热热阻;辐射换热;
Abstract: Shading shield themselves do not take any heat, the addition of a cover hot plate can increase its insulation thermal resistance between the two radiative surface, thereby reducing the radiation heat transfer between them, we can see to cover the hot plate has the role of radiation insulation. This paper introduces the use of cover hot plate, further analysis of the works cover the hot plate and draw relevant conclusions can bring inspiration to readers.Key words: cover heat shields (board); insulation thermal resistance; radiation heat transfer
中图分类号:O432文献标识码:A文章编号:2095-2104(2012)
0.前言
遮热板作为一种隔热、热防护和保温节能技术被广泛地应用于热辐射防护设备等工程中。在实际工程建设中常用隔热板来隔离干扰物质以保护物料,或减少辐射热量对建筑物的影响;使用带有遮热罩的抽气式热电偶来测量气体温度可避免由辐射隔热引起的测量误差;冶金上加一遮热板于平顶式加热炉的均热段与加热段之间,可确保物料在加热段整体加热,防止加热段的热量辐射影响到均热段。
1.平面遮热板的工作原理
我们可以假设有两块平板F1和F2,以及一遮热板F3,把它们的黑度和温度分别设为ε1、T1,ε2、T2和ε3、T3,而T1>T2,平板均为无限宽大,如图一所示。
图一遮热板原理
当仅有两块平板而无遮热板时的辐射换热量可表示为:
(1)
现于平板F1和F2两面间加一块遮热板F3。假设遮热板本身的导热热阻极小可忽略不计,那么遮热板两侧的温度可视为一样,均为T2,遮热板的黑度为ε3。由于遮热板本身不带走任何热量也不起热,它主要在热流通路中附加了一个的隔热热阻,利用遮热板F3进行F1→F2面的辐射,层对层进行,F1→F3→F2,即F1先对遮热板F3进行辐射,接着遮热板F3再对F2进行辐射。……