双源CT双能量成像联合影像组学在鉴别甲状腺良恶性结节中的应用价值
2025-08-15冯俏岳志斌孙櫻函全江海程留慧
Applicationvalueofdual-source dual-energy CTcombinedwithradiomicsindiferentialdiagnosisofbenignand malignant thyroid nodules
FENGQiao1,2,YUEZhibin’,SUNYinghan1²,QUAN Jianghail,²,CHENGLiuhui’
1DepartmentofRdiolgyFirstAfliatedHospitalofHnanUniversityofineseMeicine,Zhengzou4ooohna;st Clinical Medical Colege,Henan University of Chinese Medicine,Zhengzhou 45oooo,China.
[Abstract]Objective:Toinvestigatethevalueofdual-sourcedual-energyCcombinedwithradiomicsindiferentialdiagnosis ofbenignandmalignantthyroidnodules.Methods:Atotalof118patientswith128thyroidnodulesconfirmedbypathology wereretrospectivelyanalyzed,inlcuding6Obenignnodulesand68malignantnodules.Allnoduleswererandomlydividedinto atrainingset(85nodules)andavalidationset(43nodules).Theclinicalandimaging featuresanddual-energyquantitative parameterswerecolected.Clinicalindependentpredictorswerescrenedandtheclinical modelwasconstructedthrough multivariatelogisticregresionanalysis.Theradiomicsfeaturesofnon-enhancedandenhancedimageswereextracted,ndthe LASSOalgorithmwasused toselecttheoptimal features toconstructtheradiomics model.Theclinicalindependentpredictors andradiomicsfeatureswereselectedtoconstructtheclinical-radiomicsmodelandanomogramwasdrawn.ROC curve wasusedtoevaluatedthediagnosiseficiency,DeLong testwasusedtocomparetheAUCvaluesofdiferentmodels,and calibrationcurveanddecisioncurvewereuesdtoevaluatethecalibrationofthemodelanditsclinicalbenefis.Results: Nodulecalcification,aspectratioandnormalizediodineconcentration(NIC)inthearterialphasewereindependentpredictors formalignant thyroidnodulesandwereusedtoconstructtheclinicalmodel.TheAUCvaluesoftheclinicalmodel inthe trainingsetandvalidationsetwere0.86OandO.848,thoseoftheradiomicsmodelwereO.937andO.918,andthoseof the clinical-radiomicsmodelwereO.967andO.937,thehighest.DeLongtestshowedthattherewasasignificantiference between the clinical-radiomics model and the clinical model in the training set( P⩽0.05 ).The calibration curve showed that thepredictionresultsoftheclinical-radiomicsmodelwereconsistentwiththeactualresults,andthedecisioncurveanalysis showedahighclinicalbeneft.Conclusion:Theclinical-radiomicsmodelinthepreoperativeidentificationofbenignand malignant thyroid nodules have high clinical value.
[Keywords] Thyroid nodules;Radiomics;Iodine concentration;Tomography,X-ray computed
甲状腺结节指甲状腺内滤泡细胞由于异常增生而形成的组织团块,是临床常见的内分泌疾病,其检出率呈逐年上升趋势[1]。临床干预多与结节性质相关,早期准确诊断可帮助治疗方案的选择,减少过度治疗。超声是甲状腺结节的首选检查方法,敏感度高,但易受操作者的主观影响[2]。常规CT检查甲状腺结节的影像学特征不典型,结节与周围甲状腺组织对比度较差,鉴别诊断困难。双源CT同时使用2种不同的X线能量采集数据,衍生的碘浓度(IC)能谱曲线斜率 (λHU) 等定量参数有助于鉴别肿瘤的良恶性。影像组学是从影像图像中提取大量多维特征,以反映肿瘤内部异质性。目前有关双源CT双能量成像联合影像组学在甲状腺良恶性结节中的鉴别诊断性能的研究较少,因此,本研究探讨双源CT双能量成像联合影像组学诊断甲状腺良恶性结节的准确率,以期为临床早期决策提供参考。
1资料与方法
1.1一般资料
回顾性收集2022年1月至2023年6月中医药大学第一附属医院经病理证实的甲状腺结节患者的临床资料及CT图像。纳入标准: ① 有手术病理结果; ② 甲状腺结节直径 ⩾5mm ③ 术前1个月内行双源CT双能量扫描。排除标准: ① 既往行手术治疗、细针穿刺活检者; ②CT 图像质量欠佳、影响图像评估及特征提取者。最终纳入118例(128个结节),其中男27例,女91例;年龄 14~77 岁,平均 (47.4±13.3) 岁;良性结节60个,恶性结节68个;以2:1的比例分层抽样,随机分为训练集85个和验证集43个。本研究获得中医药大学第一附属医院伦理委员会批准(批号:2022HL-264-01)。……
