回龙抽水蓄能电站库盆渗漏特性研究
2021-12-08谢遵党吕小龙宋修昌马峰
谢遵党 吕小龙 宋修昌 马峰



摘 要:抽水蓄能电站水位升降频繁、外部环境多变,长期运行过程中库盆渗控体系的老化问题十分突出。渗漏量是评价抽水蓄能电站库盆运行状態的关键监测指标,将库盆渗漏通道划分为堰型缺陷和深孔型缺陷,确定了水压、温度、时效分量影响因子。通过系统研究库水位、温度、时间对渗漏量的影响,建立了抽水蓄能电站库盆渗漏量统计模型。基于回龙抽水蓄能电站上水库库盆渗漏监测数据,验证了模型的准确性,为回龙电站库盆防渗治理提供了理论依据。
关键词:库盆渗漏;堰型缺陷;深孔型缺陷;统计模型;回龙抽水蓄能电站
中图分类号:TV641
文献标志码:A
doi:10.3969/j.issn.1000-1379.2021.11.025
引用格式:谢遵党,吕小龙,宋修昌,等.回龙抽水蓄能电站库盆渗漏特性研究[J].人民黄河,2021,43(11):133-136.
Study on Reservoir Basin Leakage of Huilong Pumped Storage Power Station
XIE Zundang LYU Xiaolong SONG Xiuchang MA Feng3
(1.Yellow River Engineering Consulting Co., Ltd., Zhengzhou 45000 China; 2.Key Laboratory of Water Management
and Water Security for Yellow River Basin, Ministry of Water Resources (Preparation), Zhengzhou 45000 China;
3.Huilong Branch of State Grid Xinyuan Co., Ltd., Nanyang 473002, China)
Abstract: Due to the frequent rise and fall of water level and the changeable external environment, the problem of reservoir basin leakage is prominent for pumped storage power station in the process of long-term operation. Leakage is a key index to evaluate the operation state of pumped storage power station basin. In this paper, the leakage channel of the reservoir basin was divided into weir-type defects and hole-type defects, the influence factors of water pressure component were determined. By systematically study the influence of reservoir water level, temperature and time on the leakage, a statistical model of reservoir basin leakage of pumped storage power station was established. Based on the leakage monitoring data of the upper reservoir basin of Nanyang Huilong pumped storage power station, the accuracy of the model was verified. At last, the time when the leakage of Huilong Reservoir basin exceeded the design limit (2,000 m3/d) was predicted, which provided a theoretical basis for the anti-seepage treatment of Huilong Reservoir basin.
Key words: reservoir basin leakage; weir-type weir type defect; hole-type defect; statistical model; Huilong Pumped Storage Power Station
随着经济社会的发展,我国用电结构和电网负荷特性发生了显著变化,电网峰谷差不断拉大和调峰容量不足的矛盾日益突出。抽水蓄能电站在电力系统中可以发挥调峰填谷、调频调相、提高供电质量等作用。目前,我国完工、在建、待建的抽水蓄能电站超过百座,早期建设的抽水蓄能电站经过长期运行,大多存在渗控体系老化问题[1-2]。抽水蓄能电站多为循环用水,水量的渗漏损失将严重影响工程的安全运行和电站经济效益的发挥。
基于工程监测资料建立数学模型,可实现对工程效应量的量化分析和预测,对保证工程安全运行具有重要意义。近年来,国内外学者在水利工程的结构健康监测领域取得了大量成果。……