APP下载

输电线路故障测距方法研究

2021-08-24彭丹阳何艺萌李丁张铭飞白苏赫

河南科技 2021年10期

彭丹阳 何艺萌 李丁 张铭飞 白苏赫

摘 要:随着信号处理技术的不断发展,行波法在输电线路故障测距方面取得了较大进步。本文综合现有行波测距法,分析不同行波故障定位方法的优缺点并进行比较。结果表明:多端行波测距方法误差远小于单端、双端行波测距法,双端行波测距法误差小于单端行波测距法。

关键词:故障定位;行波法;单端行波测距;双端行波测距;多端行波测距

中图分类号:TM755文献标识码:A文章编号:1003-5168(2021)10-0027-03

Research on Fault Location Method of Transmission Line

—Taking Traveling Wave Ranging Method as an Example

PENG Danyang HE Yimeng LI Ding ZHANG Mingfei BAI Suhe

(North China University of Water Resources and Electric Power,Zhengzhou Henan 450000)

Abstract: With the continuous development of signal processing technology, traveling wave method has made great progress in fault location of transmission lines. In this paper, the advantages and disadvantages of different traveling wave fault location methods were analyzed and compared. The results show that the error of multi terminal traveling wave ranging method is far less than that of single terminal and double terminal traveling wave ranging method, and the error of double terminal traveling wave ranging method is less than that of single terminal traveling wave ranging method.

Keywords: fault location;traveling wave method;single terminal traveling wave location;double terminal traveling wave location;multi terminal traveling wave location

输电线路承担着电力传输的重任,其可靠性决定着整个电网的安全运行。当某段线路突发故障后,迅速且精准地进行故障定位,进而尽快消除故障,是保障输电线路稳定运行的重中之重。当前,输电线路故障点检测方法主要包括单端行波测距法、双端行波测距法和多端行波测距法[1-6]。这三种方法无论是在设备成本上还是基本原理上都存在显著差异。

1 行波测距方法与原理

1.1 单端行波测距

1.1.1 单端行波测距原理。①故障发生距离小于线路总长的一半。当输电线路上的故障距离小于线路总长度的一半时,所测得的第二个行波的波头应是来自故障点的反射波。单端行波测距原理图如图1所示,故障距离[dMf]的计算公式如式(1)所示。

[dMf=12(tM2-tM1)v]                          (1)

式中:[v]表示行波传播速度,m/s;[tM1]表示故障行波到达点M的时间,s;[tM2]表示经故障点反射波到点M的时间,s。

②故障发生距离大于总线路长度的一半。故障发生位置超过线路总长度的一半时,第二个故障行波的波头是对侧母线的反射。……