冬季大体积混凝土施工浅谈
2021-08-09马如赵长明
马如 赵长明



摘 要:随着城市建设的迅猛发展,对于建设工程工期的要求,冬季施工已是不可避免的选项,而大体积混凝土的冬季施工问题,特别是地下室底板部分的施工技术问题也逐步增加。该工程在针对大体积混凝土底板的浇筑时,针对该项目施工中采用的施工工艺,包括添加外加剂法、混凝土原材料蓄热法,尤其是空白低温混凝土施工工法做出分析。
关键词:冬季施工 大体积混凝土 温度应力 裂缝控制 保温
中图分类号:TU755.8 文献标识码:A文章编号:1672-3791(2021)04(b)-0091-04
Discussion about Construction of Mass Concrete in Winter
MA Ru1 ZHAO Changming2
(1.Anhui Kechuang Engineering Project Management Co.,Ltd., Hefei, Anhui Province, 230003 China; 2.Sino Rsing-SunCongstruction Group Co., Ltd., Chuzhou, Anhui Province, 239000 China)
Abstract: With the rapid development of urban construction, winter construction is an inevitable option for the requirements of construction period, and the winter construction problems of mass concrete, especially the construction technology problems of basement floor, are gradually increasing. In this project, when pouring the mass concrete floor, the construction technology used in the construction of this project, including the method of adding admixtures, the method of heat storage of concrete raw materials, especially the construction method of blank low temperature concrete, is analyzed.
Key Words: Winte rconstruction; Mass concrete; Temperature stress; Crack control; Preserve heat
隨着城市建设的迅猛发展,对于建设工程工期的要求,冬季施工已是不可避免的选项,而大体积混凝土的冬季施工问题,特别是地下室底板部分的施工技术问题也逐步增加。为此,根据笔者实际接触的部分项目,在此对于冬季大体积混凝土施工进行研究与分析。
1 工程概况
滁州市某大厦主楼基础为钢筋混凝土筏板基础,厚度为2.5 m,长为45 m,宽度为18 m,底板埋深为-5 m,底板配筋为三层双向钢筋,间距为100~150 mm。该层板设计混凝土等级为C30,抗渗要求为S6级,混凝土总量约为2 000 m3。
2 施工工艺浅析
正常情况下,对于混凝土特别是地下室底板部分的大体积混凝土施工,混凝土浇筑养护过程中因为温度收缩应力过大从而形成的温度应力裂缝是必须要得到控制的,因此为了减少乃至避免此类问题的产生,施工单位一般采取选用类似低热硅酸盐水泥等水化热较低的材料和经过降温处理的水等给原材料降温的措施来控制水化热的增加,减小混凝土的内外温差。……