实验室中普通玻璃器皿微量元素硼等测定的可行性
2021-06-29问寻
问寻



摘 要:针对实验室中普通玻璃器皿硼等微量元素测定过程复杂、测定精密度和准确度低的问题,本研究应用电感耦合等离子体原子发射光谱方法(ICP-AES)对其进行测定,解决了以上问题。通过ICP-AES方法,快速准确测定了普通玻璃器皿中硅、硼、钙、铁等元素,同时该方法的检出限和精密度、准确度等满足了实验室普通玻璃器皿类产品的检测要求。
关键词:ICP-AES;微量元素;元素测定;玻璃
中图分类号:TQ171 文献标识码:A 文章编号:1001-5922(2021)05-0039-04
Feasibility of Determination of Trace Element Boron in Ordinary Glassware in Laboratory
Wen Xun
(Xi an Medical University, Xi an 710100,China)
Abstract:In order to solve the problems of complex process, low precision and accuracy in the determination of boron and other trace elements in ordinary glassware in the laboratory, inductively coupled plasma atomic emission spectrometry (ICP-AES) was applied to determine boron and other trace elements in common glassware , and solve the above problems. Through ICP-AES method, silicon, boron, calcium, iron and other elements in ordinary glassware were determined rapidly and accurately. At the same time, the detection limit, precision and accuracy of the method met the detection requirements of ordinary glassware products in the laboratory.
Key words:ICP-AES; trace elements; element determination; glass
實验室中普通玻璃器皿常用于盛装各类实验化学试剂,因此它的各种元素含量或将对某些实验结果造成一定的影响,故在其生产中需要严格把控各元素的含量。现有的普通玻璃器皿微量元素测定的方法包括化学还原分光光度法[1]、EDTA络合滴定法[2]、乙酸锌反滴定法等,这些方法虽然能测定一个或两个元素,但由于操作过程复杂,工作量大,且测定范围受限,测定精度低,因此不适用于玻璃器皿中多种元素的测定,故探讨一种可同时测定多种元素且具有高测量精度和准确度的分析方法十分必要。本研究探讨了ICP-AES在测定实验室中普通玻璃器皿微量元素硼等测定的可行性,并通过实验验证了该测量结果的准确性和可靠性。实验结果表明,该方法不仅操作简单,且测量精度和准确度满足实验室中普通玻璃器皿生产的检测要求。
1 材料与方法
1.1 仪器与试剂
本研究的主要仪器是由德国斯派克生产的ICP光谱仪,该仪器的工作条件如表1所示。……