APP下载

Determination of seven active components in Salvia miltiorrhiza herb by matrix solid phase dispersion combined with ion liquid extraction followed by high performance liquid chromatography

2021-05-11BoHongYanpingWangYinglongHanWenjingLi

Bo Hong,Yanping Wang,Yinglong Han,Wenjing Li

College of Pharmacy,Qiqihar Medical University,Qiqihar 161006,China

Abstract A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid (SGSIL) combined with matrix solid phase dispersion (MSPD) followed by high performance liquid chromatography (HPLC) with ultraviolet detection (UV) is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid [BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection (LOD,S/N=3) of 0.0122-0.8788 μg/mL for standard solution,limit of quantification (LOQ,S/N=10) of 0.0406-2.9292 μg/mL for standard solution,wide linear range from 1.56 to 2000 μg/mL for all compounds for standard solution,correlation coefficients (r) of more than 0.9990,acceptable reproducibility (relative standard deviations,RSDs < 3.54%),and precision of RSDs < 3.36% for intra-day,RSDs < 3.50% for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.

Keywords: high performance liquid chromatography (HPLC);silica gel supported ionic liquid (SGSIL);matrix solid phase dispersion(MSPD);Salvia miltiorrhiza (SM);determination

1 Introduction

In recent years,with the expansion of disease spectrum,the arrival of aging society and the change of health concept,the advantages of traditional Chinese medicine (TCM) have become more and more obvious.Both health care and medical care are paid more and more attention by academia and industry [1-3].

Salvia miltiorrhiza

(SM),the dry root and the rhizome of

Labiatae Salvia

perennial herbs,with the functions of removing blood stasis,promoting blood circulation and regulating menstruation,is an important traditional Chinese medicine in gynecology [4].Traditionally,it is also used to treat cardiovascular diseases.Modern studies have also found that SM has organ protection function,anti-bacterial activity,anti-inflammatory property,brain protection function and anti-tumor effect [5-7].The main active components are fat soluble tanshinones,such as dihydrotanshinone I,cryptotanshinone,tanshinone I,and tanshinone II A,and water soluble phenolic acids,such as tanshinol,rosmarinic acid and salvianolic acid B.The above seven compounds with different polarities are the material basis of SM,which have been reported to show strong pharmacological activities [8,9].Tanshinol can improve microcirculation and inhibit platelet aggregation.It also showed synergistic effects and reduced side effects when combined with radiotherapy on lewis lung cancer in mice [10,11].Rosmarinic acid has strong anti-inflammatory,anti-bacterial,anti-viral and anti-tumor effects.Rosmarinic acid has strong antioxidant activity,which helps to prevent cell damage caused by free radicals [12-14].Pharmacological studies have shown that salvianolic acid B has obvious antioxidant effects,and can inhibit platelet aggregation,inhibit thrombosis and avoid myocardial ischemiareperfusion injury [15-17].Dihydrotanshinone I has antimicrobial,hypolipidemic,liver protecting,and anti-angiogenic activities [18-20].Cryptotanshinone,as a representative component of SM in activating blood circulation,has shown good prospects in cardiovascular diseases,anti-cancer,anti-bacterial and anti-inflammatory effects,therefore mainly used in metabolic disorders and neurodegenerative diseases [21,22].Tanshinone I has been proved to inhibit the growth of tumor cells through inducing apoptosis,especially hepatocellular carcinoma [23,24].Tanshinone II A can improve coronary circulation,inhibit the occurrence of thrombosis,improve myocardial contractility and promote myocardial regeneration [25-27].Therefore,the complete extraction process (Fig.1)and analysis of the seven compounds are particularly crucial for the quality control and pharmacological investigations of herbal SM.

Fig.1 The whole process of the experiment

Conventional extraction methods of SM include ultrasonic-assisted,microwave-based and supercritical COfluid extraction,which are determined by HPLC-UV or UPLC-MS/MS [28-30].The main active components in SM are unstable to heat,and the post-treatment process of ethanol extraction (storage,recovery of ethanol,concentration,and drying) is another main process of thermal degradation loss,so SM is not suitable for heat reflux extraction.Traditional detection methods for Chinese herbal medicine,which consume a lot of organic solvents,take a long time and have low accuracy,are difficult to detect large-scale samples quickly.It is urgent to develop a simple,environment-friendly and rapid extraction method.Matrix solid phase dispersion (MSPD),as a simple sample extraction technology,has the advantages of less extraction time,less solvent consumption and simultaneous extraction and purification [31,32].It was widely used in food safety analysis,expert testimony analysis,bioengineering and other fields.More and more components are extracted from solid environments by MSPD technology,which has gradually become a method of extracting natural products from traditional Chinese medicine.The greatest advantage of MSPD method is that it combines the homogenization,extraction and purification processes of traditional sample pretreatment,and omits centrifugation and sample transfer process to avoid sample loss [33-36].

In this paper,ionic liquid was introduced into solid phase extraction.Compared with traditional organic solvents,ionic liquid has the advantages of low vapor pressure,wide viscosity range,strong solubility and high thermal stability.Ionic liquids have become popular green solvents,applied to the extraction and analysis of traditional Chinese medicine by more and more scholars.As the solvent for extracting effective components of traditional Chinese medicines,ionic liquids can improve extraction efficiency by increasing interaction with extracts.Direct injection can improve the shape and resolution of chromatographic peaks.

Instead of using solid phase dispersion absorbents,such as florisil,silica gel,neutral diatomite,deactivated octadecyl (C) bonded silica packing,and neutral alumina,this study combined ionic liquids with matrix solid-phase dispersion method to immobilize ionic liquids in the micropore of silica gel,enlarge surface area and improve adsorption performance.As a new adsorbent,silica gel supported ionic liquid (SGSIL)was used to extract 7 target compounds from SM in the present study.To the best of our knowledge,SGSIL-MSPD technique with HPLC was firstly used to simultaneously determine from SM the 7 compounds with different polarities,including liposoluble tanshinones (dihydrotanshinone I,cryptotanshinone,tanshinone I,tanshinone II A) and water soluble phenolic acids (tanshinol,rosmarinic acid and salvianolic acid B).The structures of the 7 compounds were shown in Fig.2.In order to obtain better extraction efficiency,parameters such as adsorbent type,sample/adsorbent ratio,eluent type and concentration were optimized.Besides,the seven compounds were extracted by conventional ultrasonic-assisted extraction method to evaluate the feasibility of the established SGSIL-MSPD method.

Fig.2 Structures of the main components of Salvia miltiorrhiza

(to be continued)

Continued fig.2

2 Materials and methods

2.1 Chemicals and reagents

Reference standards of tanshinol (Lot:180328,purity > 98%),salvianolic acid B (Lot:181008,purity > 98%),dihydrotanshinone I (Lot:181019,purity > 98%),and rosmarinic acid (Lot:181018,purity > 98%) were purchased from Beijing Laiyao Biotechnology Co.,Ltd.Reference standards of cryptotanshinone (Lot:110852-201807,purity >99%),tanshinone I (Lot:110867-201607,purity >99%),and tanshinone II A (Lot:110766-201721,purity > 99.5%) were purchased from National institutes for food and drug control.Florisil (75-150

μ

m,80 A),silica gel (48-75

μ

m,60 A),neutral diatomite (150-250

μ

m,80 A),deactivated octadecyl (C) bonded silica packing (40-63

μ

m,60 A),neutral alumina (70-150

μ

m,60 A),and 1-butyl-3-methylimidazolium chloride [CMIM][Cl]were purchased from Qiqihar Longsha district Beidi teaching laboratory supplies agency.HPLC grade acetonitrile and methanol were purchased from Oceanpak Technologies Inc.,Sweden.HPLC grade phosphoric acid was purchased from Tianjin komeo chemical reagent Co.,Ltd.Deionized water was purified in a Mili-Q academic ultra pure water system (Millipore,Milford,MA,United States).Other chemical reagents were analytical grade.All solutions were filtered by a 0.22

μ

m filter membrane before HPLC analysis.

2.2 Plant material

6 batches of SM and its processed products were collected from different regions of China(Anhui Bozhou,Anhui Liu’an,Anhui Dingyuan,Anhui Tongling,Hebei,and Sichuan) and authenticated by Dr.Lina Guo (Qiqihar Medical University).All samples were dried at 60 ℃ for 24 h,pulverized by a pulverizer (Yima Leyijia Trading Co.,Ltd.),and then passed through a 100 mesh sieve.

2.3 Preparation of standard solutions

Standard stock solutions of tanshinol,rosmarinic acid,salvianolic acid B,dihydrotanshinone I,cryptotanshinone,tanshinone I,and tanshinone II A were separately prepared in methanol.Tanshinol (12.6 mg),rosmarinic acid (10.92 mg),salvianolic acid B (14 mg),dihydrotanshinone I (8.75 mg),cryptotanshinone(7 mg),tanshinone I (14 mg) and tanshinone II(17.5 mg) were accurately weighed and put into 2 mL,1 mL,1 mL,25 mL,10 mL,5 mL and 25 mL volumetric flasks respectively,dissolved in methanol by ultrasound and shaken well.The mixed reference stock solution was stored in a refrigerator at 4 ℃ for later use.

2.4 High performance liquid chromatography analysis

The chromatographic analysis was performed on a LC-1000 HPLC system (Shandong Lunan Ruihong Chemical Instruments Co.,Ltd.,Shandong,China).The workstation controlled by Easy Chrom software was employed to collect and analyze data.Separation was carried out on a Diamonsil HPLC Ccolumn (250 mm × 4.6 mm,5

μ

m,Beijing Dicoma Technology Co.,Ltd.) at the flow rate of 1 mL/min.The mobile phase consisted of water containing 0.05% phosphoric acid (eluent A) and acetonitrile(eluent B).The detailed gradient elution was as follows:0-10 min,90-80% A;10-32 min,80-76%A;32-40 min,76-72% A;40-50 min,72-52% A;50-80 min,52-52% A;80-90 min,52-20% A;90-100 min,20-15% A.The elution program was run for 5 min.The column temperature was maintained at 25 ℃ and the injection volume was 20

μ

L.The detection wavelength was set at 240 nm.Under the above chromatographic conditions,the chromatographic peaks of analytes including samples and standard solutions were separated (Fig.3).

Fig.3 High-performance liquid chromatograms of standard mixture and sample (A.reference substance chromatogram;B.SM samples chromatogram;1.tanshinol,2.rosmarinic acid,3.salvianolic acid B,4.dihydrotanshinone I,5.cryptotanshinone,6.tanshinone I,7.tanshinone II A)

2.5 Preparation of silica gel supported ionic liquid(SGSIL)

SGSIL was prepared by direct impregnation method.Silica gel was dried in an oven at 160 ℃ for 3 h,and immersed in methanol solution containing ionic liquid [BMIM]Br (10%).Then the mixture was evenly stirred at room temperature,and dried to constant weight in an oven at about 160 ℃.Finally,the white powder,ionic liquid immobilized on silica gel was obtained as adsorbent.In order to judge whether the ionic liquid was immobilized on silica gel surface,we compared the difference between silica gel and ionic liquid immobilized on silica gel using infrared spectroscopy and scanning electron microscopy.

2.6 Matrix solid phase dispersion with ionic liquid procedure

1.0 g of previously crushed aliquot samples and 2.0 g of adsorbents (SGSIL,florisil,silica gel,neutral diatomite,deactivated octadecyl (C)bonded silica packing,and neutral alumina) were put into a mortar to mix.The mixture was grinded with a pestle for 10 min until it was completely dispersed.Then,the mixture was transferred into a 10 mL polypropylene tube.6 mL elution reagent ([BMIM]BF) was added to elute the target compounds.The eluent liquid was collected and filtered by 0.22

μ

m microporous membrane,and 20

μ

L of filtrate was injected into the HPLC instrument for analysis.

Timmy, I told him, your finger is going to be perfectly10 fine. Let s wait until it s completely healed before we tell anybody about this special technique.

2.7 Ultrasonic and refluxing extraction

According to

Chinese Pharmacopoeia

(2015) [37],0.3 g of dried SM samples (passed through sieve No.3) were accurately weighed and mixed with 50 mL methanol in a 100 mL Erlenmeyer flask.The mixture was then extracted ultrasonically(42 kHz,140 W) for 30 min and the weight loss of the solution was complemented by methanol.The extract solution was finally filtrated by 0.22

μ

m filter membrane and 20

μ

L filter liquid was injected into the HPLC instrument for further analysis.10.0 g of dried and crushed

Salvia miltiorrhiza

samples were accurately weighed in a 500 mL flask,and then 200 mL 50% ethanol was added into it for reflux extraction at 60 ℃ for 1.5 h.Two parallel operations were performed,and the extracts were filtrated and merged.All liquids were concentrated to 100 mL under vacuum,and then filtrated by 0.22

μ

m filter membrane.According to the corresponding chromatographic conditions,the target components were determined and the content was calculated.

2.8 Optimization of MSPD extraction process parameters

In order to efficiently extract the target compounds,several experimental parameters including the type of adsorbent,the ratio of sample to adsorbent,type and volume of the elution solvent were studied three times.Several adsorbents were studied,including SGSIL,florisil,silica gel,neutral diatomite,deactivated octadecyl (C)bonded silica packing and neutral alumina.1.0 g SM samples and 0.5,1,1.5,and 2.0 g adsorbents were transferred into a mortar,and then eluted with different types of ion liquids such as [BMIM]BF,[CMIM]Cl,[BMIM]PF,[HMIM]BFand [OMIM]BF2,4,6,8,and 10 mL of elution reagents were added into the polypropylene tube.

3 Results and discussion

3.1 Optimization of the IL-MSPD method

In order to obtain the maximum extraction efficiency,different MSPD parameters were optimized and experiment conditions such as the adsorbent,adsorbent-sample ratio,eluting solvent,and volume of solvent were investigated.

3.2 Adsorbent

It is important to employ a suitable dispersing adsorbent in the development of the MSPD procedure.The adsorbent can be used not only as a disruption and dispersion agent that extract the target compounds from SM,but also as a purificant that removes the interfering substance of matrix.In the present study,six types of adsorbents were evaluated.As Fig.4 shows,the analytes had the strongest retention when silica gel and neutral alumina were used as adsorbent.The reason might be that the compounds were too tightly bonded with the adsorbent to be separated easily.So in the present research,we developed a new adsorbent of silica gel supported ionic liquid (SGSIL) on the basis of silica gel to extract the main active compounds from SM.Although Chad higher extraction efficiency,it was not significantly better than SGSIL.One probable reason was that SGSIL adsorbent combined the high absorptivity of silica gel with the good extraction ability and solubility of ionic liquids to improve the mass transfer rate and recovery of target compounds from SM.Therefore,SGSIL was chosen as the optimal adsorbent for the subsequent extraction procedure.

Fig.4 Effect of adsorbent types on extraction

3.3 Ratio of sample to adsorbent

The mass ratio of sample to adsorbent is a significant parameter in the extraction process,which will affect the extraction yield of the target compounds from the herbal samples.The appropriate ratio of sample to adsorbent can not only guarantee that the sample is completely homogenized and dispersed in the adsorbent,but also reduce the loss of sample in the extraction procedure.It can be seen from Fig.5 that when the ratio of sample to adsorbent changed from 1:1 to 1:2,the peak areas of the seven target compounds gradually increased.In contrast,the peak area from 1:2 to 1:2.5 did not increase,but decreased slightly.The possible reason was that in the extraction process of traditional Chinese medicine,we used the ionic liquids immobilized on silica gel (SGSIL) as adsorbent,and the target compounds interacted not only with silica gel,but also wIth [BMIM]Br immobilized on the surface of silica gel.The larger the amount of adsorbent,the stronger the molecular interaction between analytes and adsorbents.When the adsorbent reached a certain value,further increment of the ratio of sample to adsorbent would lead to the decrease of extraction efficiency.The reason might be that the excessive adsorbent made the interaction between the seven compounds and SGSIL so strong that the compounds were difficult to elute.Therefore,the ratio of sample to adsorbent was set at 1:2.

Fig.5 Effect of ratio of sample to adsorbent

3.4 Type of eluting ionic liquid

In order to obtain good extraction efficiency for target analytes,we evaluated [CMIM]Cl,[OMIM]BF,[HMIM]BF,[BMIM]BFand [BMIM]PFas elution solvent.The elution solvent should have a polarity similar to that of the target analytes,which is beneficial to disrupt the interaction between the target analytes and the adsorbent.The results(Fig.6) showed that different ion liquids would affect the extraction yield of the target analytes in the SM during elution.The peak areas of target compounds were largest for [BMIM]BFamong the five eluting ionic liquids.This phenomenon could be ascribed to the ability to transfer the target analytes from adsorbent to eluting ionic liquid,and finally extract the target compounds to the maximum extent.[BMIM]BFwas the optimum extraction liquid for further experiments.

Fig.6 Effect of the types of eluting ion liquids

3.5 Volume of ionic liquid

The volume of ionic liquid is also a crucial parameter affecting the extraction yield of the target compounds in the elution process.In order to obtain the highest extraction efficiency with the minimum volume of ionic liquid,ionic liquid ranging from 2 mL to 10 mL were studied.Fig.7 showed that the content of the seven compounds increased from 2 to 10 mL.The reason could be that with the increase of eluant volume,interaction between analytes and eluant became stronger.However,when the volume increased over 8 mL,the peak areas of the seven compounds remained unchanged.Excessive solvent caused unnecessary waste.Therefore,8 mL of [BMIM]BFwas used in the following MSPD extraction procedure.

Fig.7 Effect of volume of ionic liquid

3.6 Method validation

3.6.1 Selectivity and linearity

The representative chromatogram (Fig.3)showed that this method could accurately and exclusively determine the seven compounds without interference from other components,impurities or degradation products.1 mL of the above standard stock solutions of the 7 compounds was taken out and mixed together to obtain the reference solution with the highest concentration point of the standard curve (900.00

μ

g/mL for tanshinol,1560.00

μ

g/mL for rosmarinic acid,2000.00

μ

g/mL for salvianolic acid B,50.00

μ

g/mL for dihydrotanshinone I,100.00

μ

g/mL for cryptotanshinone,400.00

μ

g/mL for tanshinone I,100.00

μ

g/mL for tanshinone IIA).A series of standard solutions were prepared by two step-bystep dilutions.The calibration curves (

n

=6) of 7 analytes were obtained by taking the peak areas as

Y

axis and the concentration in

μ

g/mL as

X

axis,which ranged from 1.56-2000.00

μ

g/mL.Table 1 showed that the correlation coefficient (

R

) of each analyte was higher than 0.9990.The results showed that the

R

values were in line with relevant standards.

3.6.2 Limit of detection and quantification

Limit of detection (LOD) and limit of quantification (LOQ) were employed to evaluate the sensitivity of the established method.They were calculated using the concentration of the analytes when the signal to noise (S/N) ratio reached 3 for LOD and 10 for LOQ respectively.The LOD of the seven compounds ranged from 0.0122 to 0.8788

μ

g/mL,while the LOQ ranged from 0.0406 to 2.9292

μ

g/mL(Table 1).

Table 1 Linearity,limits of detection (LOD),limit of quantification (LOQ),and repeatability of the proposed method(n =6)

3.6.3 Repeatability

The repeatability was evaluated using six parallel IL-MSPD extracts from a batch of SM samples.As shown in Table 1,the values of relative standard deviations (RSDs) were all less than 3.54%,indicating that the developed method had good repeatability.

3.6.4 Precision,stability and recovery

We separated precision test into two parts:intra-day and inter-day precision by determining the relative standard deviations (RSDs) at three levels of concentration in six replicates of each compounds.Intra-day precision and inter-day precision were tested in a single day and within consecutive 3 d,respectively.Validation results were presented in Table 2.The accuracy for intra-day precision was within the range of 93.6-104.2% (RSD ≤ 3.36%) and that for inter-day precision was within the range of 93.3-104.7% (RSD ≤ 3.50%).

Table 2 The results of precision and stability

Stability was evaluated using the accuracy tests of three concentration levels of the seven compounds at room temperature for more than 24 h.The accuracy of the seven compounds ranged from 95.2% to 102.4%,and the RSDs were all no more than 3.17%.The results showed that the analytes were stable within 0 to 24 h at room temperature.

Recovery was used to evaluate the accuracy of analysis method and loss in the operation process.By analyzing the spiked sample in triplicate,recovery tests were performed to verify the accuracy of the proposed method.Unspiked sample and spiked samples were simultaneously extracted using the optimum SGSILMSPD procedures.The results were listed in Table 3.The average recovery of 7 compounds ranged from 96.4% to 102.5%,with RSDs all less than 3.45%,which indicated that the proposed SGSIL-MSPD method was reliable and effective.

Table 3 The results of recovery test (n =6)

3.7 Application

The above analysis results showed that the proposed method had application value.Using the developed SGSIL-MSPD method,the target compounds in six batches of crude SM were analyzed under the optimized conditions.The contents of tanshinol,rosmarinic acid,salvianolic acid B,dihydrotanshinone I,cryptotanshinone,tanshinone I and tanshinone II A in crude SM were in the range of 0.100-0.118,2.221-2.412,31.97-35.29,0.188-0.252,0.301-0.528,1.246-1.468 and 1.131-1.294 mg/g,respectively (Table 4).

Table 4 Contents of the seven compounds of SM samples from 6 batches (n =6)

In order to compare the proposed SGSILMSPD method with conventional ultrasonic assisted extraction method in

Chinese pharmacopoeia

(2015) (We didn’t choose the heating extraction because of the ingredients in SM are not suitable for extraction by heating system.The water soluble components in SM are highly sensitive to heat and the lipo soluble components are easy to sublimate,so components loss and thermal instability will occur during long-term heat treatment),the contents of the seven target compounds from the same batch of SM were determined by these two methods.The results showed that SGSIL-MSPD method was more efficient and the extraction rate was higher.The total contents of cryptotanshinone,tanshinone I and tanshinone II A from different regions were all over 0.25%.The contents of salvianolic acid B were all over 3.0%.The contents of the above three active compounds all met the requirements of extracting SM in

Chinese pharmacopoeia

(2015).

3.8 Comparison with other methods

To evaluate the performance of the proposed SGSIL-MSPD method,the most commonly used ultrasonic-assisted extraction method was introduced,and the sample amount,extraction solvent,solvent volume and extraction time were compared.As shown in Table 5,the developed SGSIL-MSPD method had less extraction time and sample amount than the ultrasonic method.Overall,these results indicated that the SGSIL-MSPD method was a rapid,simple and environmentfriendly method for extracting the main active compounds from SM samples.

Table 5 Comparison of the SGSIL-MSPD method with other methods in the determination of compounds in SM sample

4 Conclusion

An environment-friendly sample pretreatment method,silica gel supported ionic liquid based matrix solid-phase dispersion (SGSIL-MSPD) with ionic liquid elution was successfully developed to extract and quantify the target analytes from

Salvia

miltiorrhiza

by HPLC.Silica gel supported ionic liquid was employed as the adsorbent to improve the adsorption capacity of compounds of different polarities.Adding molecular solvents into ionic liquids and then combining it with silica gel to make the adsorbent SGSIL is one of the innovations in this paper.Ionic liquid as elution solvent is another innovative extraction solution in the MSPD process.Active components were easily separated from the herbal matrix,and then easily extracted and eluted from the adsorbent using ion liquid to promote the transfer process.The use of green ionic liquid reduced the environment pollution.Compared with other extraction methods (ultrasonic extraction),the present method is rapid,time-saving and efficient.This proposed method can be used for the determination of compounds with different polarities from other traditional Chinese medicines.

Author contributions

Bo Hong and Wenjing Li designed the experiments.Yanping Wang and Yinglong Han performed the experiments.Bo Hong wrote the manuscript.

Funding

This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University (QMSI2020B-03,hosted by Wenjing Li).

Conflict of interest statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.


登录APP查看全文