流动注射法测定水中总氰化物的不确定度
2020-09-26王素贞
王素贞

[摘要] 目的 研究流动注射法测定水中总氰化物的不确定度。方法 选择6份水样本进行检测,观察其中总氰化物的不确定度。结果 样品测量数据下均值为19.54 μg/L、标准差为0.254 μg/L,相对标准偏差为0.012。其中1~6号标准溶液分别为2、2、5、10、20、50,峰高yi、平均峰高y-均出现明显在增高的情况。结论 对于水中总氰化物不确定度测定,可使用流动注射法测定,具有自动进样、分析速率快、试剂耗量低等优点。
[关键词] 流动注射法;水中总氰化物;不确定度
[中图分类号] R123 [文献标识码] A [文章编号] 1672-5654(2020)06(a)-0186-03
[Abstract] Objective To study the uncertainty of determination of total cyanide in water by flow injection method. Methods Six water samples were selected for testing and the uncertainty of total cyanide was observed. Results The average value of the sample measurement data was 19.54 μg/L, the standard deviation was 0.254 μg/L, and the relative standard deviation was 0.012. Among them, the standard solutions Nos. 1 to 6 are 2, 2, 5, 10, 20, 50, and the peak height yi and the average peak height y- were obviously increased. Conclusion For the determination of total cyanide in water, flow injection method can be used. It has the advantages of automatic sampling, fast analysis rate, low reagent consumption, etc.
[Key words] Flow injection method; Total cyanide in water; Uncertainty
近年来随着人们生活经济条件不断改善,消费观也在不断出现变化,对水资源质量的追求也在不断提升[1]。而生活性氰化物中毒以口服为主,口腔黏膜和消化道能充分吸收,其属于无色气体,仅出现淡淡的苦杏仁味,但少部分人难以闻到[2]。氰化物作为水污染的主要物质,在天然水中含量较少,受到石油化工、煤气等工业影响,水体会出现污染的情况,饮用天然矿泉水是直接饮用的,但氰化物均属于高毒物质,长期摄入氰化物的饮用水,会使得患者出现头痛、贫血等慢性中毒的情况[3]。传统的非平衡条件下化学处理过程(如离子交换、萃取)已经被改造成自动在线操作,几十秒钟即可完成,可以大大减少试剂和样品的消耗,有效减少污染的机会,并提高分析方法的灵敏度。与传统方式相比,流动注射法省去手工蒸馏、萃取、显色的步骤,节省了时间,准确度较高,该文通过将流动注射法进行研究,报道如下。……