1 000 MW超超临界冲动式汽轮机通流改造及效益分析
2020-05-19张彬赵金涛胡雪梅
张彬 赵金涛 胡雪梅


摘 要:TOSHIBA原型1 000 MW超超临界汽轮机存在级间焓降过大、调节级效率偏低、中压进汽部分需要冷却、低压缸采用非落地轴承等设计缺陷。在长期运行中,汽轮机隔板疲劳会导致宏观裂纹,汽轮机热耗偏离设计值至少200 kJ/(kW·h),低压轴承在高真空下出现振动突增。基于上述问题,本文结合机组的实际运行情况,提出一套较为理想的汽轮机通流部分改造方案并进行经济性分析,在增量机组困难的现状下,这对于百万机组的经济性提升具有一定的指导意义。
关键词:通流改造;全周进汽;节流调节;宽负荷叶片
中图分类号:TM621文献标识码:A文章编号:1003-5168(2020)08-0128-03
Transformation and Benefit Analysis of 1 000 MW Ultra-supercritical Impulse Steam Turbine
ZHANG Bin ZHAO JintaoHU Xuemei
(Pingdingshan Power Generation Branch, Henan Electric Power Co., Ltd. of SPIC,Pingdingshan Henan 467000)
Abstract: The TOSHIBA prototype 1 000 MW ultra-supercritical steam turbine has design defects such as excessive interstage enthalpy drop, low regulating stage efficiency, low-pressure steam inlet parts requiring cooling, and low-pressure cylinders using non-ground bearings. In long-term operation, the fatigue of the turbine diaphragm will cause macro cracks, the heat loss of the turbine will deviate from the design value by at least 200 kJ/(kW·h), and the low-pressure bearing will experience a sudden increase in vibration under high vacuum. Based on the above problems, this paper combined with the actual operation of the unit, put forward a set of more ideal steam turbine flow-through reconstruction scheme and economic analysis, which had certain guiding significance for the economic improvement of millions of units under the current situation that the incremental unit was difficult.
Keywords: through-flow reformation;full-period intake steam;throttling adjustment;wide-load blade
根據国家发展和改革委员会、原环境保护部和国家能源局联合下发的《煤电节能减排升级与改造行动计划(2014—2020年)的通知》(发改能源〔2014〕2093号)、《国家能源局综合司关于分解落实煤电节能减排升级改造目标任务的通知》(国能综电力〔2014〕767号)要求,原则上,各单位每年技术改造资金中,在去除脱硫、脱硝、除尘器和灰坝等重大环保改造项目资金外,节能改造的投入应达到其余技改资金的40%。对于汽机通流、供热改造等重大节能改造项目,经技术方案论证可行且资本金内部收益率≥8%的应尽早安排改造。因此,本次改造研究原则为:汽轮机原有基础不变,各抽汽口参数变化不超过5%,抽汽级数不变,汽轮机旋转方向不变[1-3]。
1 机组设备概况
1.1 汽轮机设备简介
某电厂汽轮机型号为N1030-25/600/600,为超超临界、一次中间再热、冲动式、单轴、四缸四排汽、双背压、凝汽式汽轮机,汽轮机磨机叶片长度为1 219 mm,设计运行背压为4.9 kPa。……