660MW超超临界机组汽动给水泵推力瓦温度高故障原因分析及处理

2019-10-24谢建勇

科技创新与应用 2019年24期

谢建勇

摘  要:近年来,超超临界机组由于其先进的技术以及优异的性能,在全国取得了广泛运用,给水泵作为汽轮发电机组不可或缺的重要辅机,其工作情况的好坏与机组的安全运行息息相关。部分660MW超超临界机组在给水泵的选择上,配置采用的是一台100%负荷的汽动给水泵及一台30%负荷的电动给水泵,若汽动给水泵运行中故障跳闸,往往意味着汽轮发电机组的跳闸解列。文章对某厂660MW超超临界机组汽动给水泵推力瓦温度高的原因进行了分析,通过排除与验证,发现平衡鼓与平衡套之间间隙过小是造成推力瓦温度高的主要原因,更换新的平衡鼓后,汽动给水泵推力瓦温度恢复正常。

关键词:汽动给水泵;推力瓦;平衡鼓;温度高;分析处理

中图分类号:TM621.3       文献标志码:A         文章编号:2095-2945(2019)24-0132-02

Abstract: In recent years, ultra-supercritical unit has been widely used in the whole country because of its advanced technology and excellent performance. Feed water pump is an indispensable auxiliary machine of turbogenerator set. Its working condition is closely related to the safe operation of the unit. In the selection of feedwater pumps, some 660MW ultra-supercritical units are configured with a 100% load steam feed pump and a 30% load electric feed pump. If the steam feed pump fails to trip during operation, it often means the tripping of turbogenerator sets. In this paper, the reason for the high temperature of thrust pad of steam feed pump in 660MW ultra-supercritical unit of a certain factory is analyzed. Through exclusion and verification, it is found that the main reason for the high temperature of thrust pad is that the clearance between balance drum and balance sleeve is too small. After the replacement of the new balance drum, the thrust pad temperature of the steam feed pump returned to normal.

Keywords: steam feed pump; thrust tile; balance drum; high temperature; analysis and treatment

引言

某厂660MW超超临界机组仅配置了一台100%负荷的汽动给水泵,生产厂家为上海KSB泵业有限公司,这是一台CHTD8/5型卧式多级筒型离心泵,轴功率为26298kW,额定流量2549t/h,总扬程3732.2m,额定工作转速5106r/min。汽动给水泵正常运行时,其轴向推力由平衡鼓、平衡盘和推力轴承共同承担。

在投产前的调试过程中,该泵非工作面推力瓦温度一直偏高,尤其是转速3500r/min以上时,非工作面推力瓦温度快速上涨至80℃以上,甚至逼近保护跳闸值(90℃),严重影响机组的带负荷调试试验,并威胁机组投产后的安全稳定运行,通过对推力瓦温度高的原因展开分析,彻底解决此故障是当前必须解决的问题。

1 汽动给水泵轴向……