浅析膨胀玻化微珠砂浆外保温层脱落的原因及防治措施
2019-10-07冯文成
冯文成



【摘 要】外墙外保温是当前建筑节能的重大措施,针对外墙外保温体系自身的特点,本论文紧密结合工程案例,着重从人、机、料、法、环等5个方面,全面分析了无机膨胀玻化微珠保温砂浆外墙保温层产生脱落的原因,根据原因制定了相应的防治措施。
【关键词】外墙保温;脱落;原因;措施
Analysis on the Cause of Exfoliation of Externally Insulating Layer of Expanded and Vitrified Microsphere Mortar and Preventive Measures
Feng Wen-cheng
(Shanghai Railway Real Estate Development & Management Co., Ltd Shanghai 200071)
【Abstract】n view of the characteristics of the external thermal insulation system, this paper, combined with the engineering case, focuses on five aspects, such as man, machine, material, method and ring, The causes of the shedding of the thermal insulation layer of the vitrified microsphere thermal insulation mortar and the corresponding prevention and control measures were formulated according to the reasons.
【Key words】External wall insulation;Loss;Reason;Measures
1. 引言
目前,民用商品住宅外墙已普遍采用外墙保温系统,不仅可以提高房屋建筑的耐久性,延长建筑物的使用寿命,还可以改善居住条件,起到隔热保温减少能量消耗的作用,是建筑节能环保中的重要一环[1]。外墙外保温层的脱落不仅存在着严重的安全隐患,还影响小区建筑的整体品质,甚至有损于企业的品牌形象,造成负面的社会影响。因此,采取有效举措防治外墙外保温层脱落具有重要的现实意义和经济社会效益。
2. 外墙保温层工程案例分析
2.1 工程概况。
XXX住宅项目是保障性住房工程,为框架剪力墙结构。该工程建筑总面积115584m2,其中包括了24~32层的七栋单体建筑,建筑最高94.6m,最低的高度69.75m。外墙外保温层面积共约101695m2,保温层厚度35mm,真石漆涂料饰面,保温材料采用了无机膨胀玻化微珠保温砂浆。
2.2 无机膨胀玻化微珠砂浆外墙保温系统分析。
该工程项目所采用的无机膨胀玻化微珠砂浆外墙外保温系统具体做法为:保温层由无机玻化微珠保温砂浆加水搅拌后,抹于墙体表面,形成无空鼓保温层。抗裂砂浆、耐碱玻纤网格布(涂料饰面)构成抗裂防护层,抗裂防护层增强了面层柔性变形、抗裂防水性能。……