空调贯流风叶的运转可靠性研究
2019-09-10曾维虎姚航
曾维虎 姚航






摘 要:针对空调使用一段时间后出现贯流风叶脱落的问题,本文从外观破损情况、橡胶件灰分测试、环境腐蚀验证和不同橡胶材料耐候方面进行分析,通过研究非金属材料橡胶制品在不同温度、环境、抗老化和耐候方面的长期可靠性,改进选型方案。
关键词:贯流风叶;运转脱落;橡胶开裂;环境腐蚀
中图分类号:TB657.2 文献标识码:A 文章编号:1003-5168(2019)25-0043-02
Research on Operation Reliability of Air Conditioning Cross Flow Blade
ZENG Weihu YAO Hang
(Geli Electric Appliances (Zhengzhou) Co., Ltd.,Zhengzhou Henan 450001)
Abstract: In order to solve the problem of cross-flow fan used in air conditioning falling off after a period of time, this paper analyzed the appearance damage, ash test of rubber parts, environmental corrosion verification, weather resistance of different rubber materials, and improved the selection scheme by studying the long-term reliability of non-metallic rubber products in different temperatures, environments, anti-aging and weathering.
Keywords: cross-flow fan;running off;rubber cracking;environmental corrosion
近期接到售后反馈,河南省新乡市出现一单空调故障,现场确认为贯流风叶脱落问题。经调查,该机安装使用时间不到半年,轴套已完全开裂脱落。之后为用户更换贯流风叶,但是使用一个月后又出现轴套脱落现象,具体情形如图1所示,事件背景如表1所示。
1 失效原因分析
研究人员对取回故障件进行全面分析,从外观破损情况、橡胶件成分分析和环境复现验证等几个方面进行排查。
1.1 失效现象
售后故障件嵌件已经完全开裂脱落。轴套端面处粘有大量橡胶碎屑,平衡片存在腐蚀现象,具体情形如图2所示。
经对开裂橡胶进一步放大观察,研究人员发现,残留橡胶出现粘连迹象,橡胶表面有明显“熔融发粘”现象(见图3)。通过分析使用环境及温度可知,空调在使用时不足以产生高温灼热现象。分析结果表明,这应为橡胶开裂后持续运行产生的橡胶碎屑。
1.2 使用环境排查
经现场调查核实,该机一直处于24h不停机工作状态,安装环境为化肥厂管道气体流量监控室,空调所处环境存在管道气体(氨气)泄漏现象。……