基于有限元法的放射性固体废物桶运输辅助装置的力学分析
2019-09-10曾祥宝魏川淋
曾祥宝 魏川淋
















摘 要:针对目前国内放射性固体废物运输效率低、安全性低等问题,笔者设计了一种放射性固体废物桶运输辅助装置,建立了运输辅助装置的三维模型,并利用ANSYS对该单元进行了有限元力学分析,重点考虑静止水平放置、倾斜30°放置、刹车制动、急转弯等四个工况下关键连接紧固部件的变形和强度。计算结果表明,固体废物桶运输辅助装置的材料强度满足设计要求,这为运输辅助装置的设计定型提供了理论依据。
关键词:有限元法;运输辅助装置;三维模型;力学分析
中图分类号:TU391 文献标识码:A 文章编号:1003-5168(2019)07-0030-05
Abstract: In view of the present domestic radioactive solid waste transportation problem of low efficiency and low security, the author designed a kind of auxiliary transport device of radioactive solid waste steel drum, a three-dimensional model of transport auxiliary device was established, and finite element mechanics analysis of the element was carried out by using the ANSYS, the emphasis was put on the deformation and strength of key fastening parts under four conditions of the static horizontal placement, the static horizontal placement, the tilt 30° placement, the brake braking, and sharp turning. The calculation results showed that the transport auxiliary device of radioactive solid waste drum conform to the requirements of the strength of materials design, this provided a theoretical basis for the design and finalization of transportation auxiliary devices.
Keywords: finite element method;transport auxiliary device;3D model;mechanical analysis
随着我国核军工、核电及民用核技术产业的发展,在核设施的运行、维护和退役等过程中产生了一定量的放射性固体废物,这些放射性废物需采取运输的方式送到指定地点进行集中处理。根据相关法规和标准,通常采用的运输模式为在废物运输前将其装入200L标准废物桶(以下简称“200L桶”),再采用抱桶叉车将200L桶放置在标准拖挂车上开始道路运输。该运输方式存在运输效率低、安全性差、作业人员所受辐照时间长等问题。为解决上述问题,研制了一套放射性废物桶运输辅助装置。为评价该装置的可靠性,本文采用ANSYS软件对放射性废物桶运输辅助装置进行力学分析,重点考虑关键连接紧固部件的变形和强度。
1 放射性固体废物运输辅助装置概述
放射性固体废物运输辅助装置主要由托盘、限位挡板、链接锚杆、托盘链接件、F型固定夹具等组成。……