480t/h CFB锅炉排烟温度偏高的原因分析及治理
2019-07-23何布朗孙耀平刘玉春邓德兵
何布朗 孙耀平 刘玉春 邓德兵
【摘 要】針对某超高压135MW 循环流化床锅炉一次风机变频改造后出现的“抢风”问题,在实际运行的冷态和热态工况下进行了诊断试验。根据诊断试验结果,提出了最优改造方案。对风机进行改造后问题得以解决。
【关键词】循环流化床;一次风机;离心风机;变频;抢风
中图分类号: TK229.66文献标识码: A文章编号: 2095-2457(2019)16-0037-002
DOI:10.19694/j.cnki.issn2095-2457.2019.16.016
Diagnose Test and Retrofit of the “Blower Pinch” of the Primary Air Fan after Coversion Refomation in a 135 MW Super-high Pressure CFB Boiler
HE Bu-lang1 SU Yao-ping2 LIU Yu-chun2 DENG De-bing1
(1.SuZhou Nuclear Power Research Institute,Suzhou Jiangsu 215004,China;
2.Dianta Shendong Power Generation Co.Ltd,Shenmu Shanxi 719300,China)
【Abstract】To clear the “blower pinch” of the primary air fan after coversion reformation in a 135 MW super-high pressure CFB boiler,a related cold and thermal diagnostic test was carried out in the primary air fan under normal working condition。Besed on the test result,an optimum reformation sheme has been obtained。The problem was finally solved by taking appropriate retrofit.
【Key words】Circulating fluidized bed; Primary air fan; Centrifugal fan; Frequency conversion; Blower pinch
1 设备概述
1.1 锅炉概述
陕西某电厂135MW机组锅炉是由无锡锅炉厂制造的UG-480/13.7-M型自然循环、单汽包、超高压循环流化床锅炉,为单炉膛一次中间再热、岛式布置。锅炉主要由炉膛、两台高温绝热式旋风分离器和一个尾部竖井烟道三部分组成。燃烧室蒸发受热面采用膜式水冷壁,水循环采用单汽包、自然循环、单段循环系统。采用水冷布风板、内嵌逆流柱型风帽。燃烧室内布置水冷屏来增加蒸发受热面。燃烧室内还布置有屏式Ⅱ级过热器和屏式热段再热器。尾部对流烟道中布置Ⅲ级、Ⅰ级过热器、冷段再热器、省煤器、空气预热器。
1.2 大修改造概述
该锅炉自投运以来,为了防止炉膛水冷壁的磨损,水冷壁四角及水冷壁顶部均敷设了耐磨混凝土;同时,屏式再热器初期运行过程中由于屏再出口管局部存在超温现象,现屏式再热器面积比原设计有所减少。以上两方面的原因导致炉膛内部受热面积比原设计下降了近150m2,造成目前整体床温运行偏高(大约950~970℃之间)。
为了满足日趋严格的环保要求,降低锅炉NOX和SO2的原始排放浓度和提高炉内脱硫效率,在保证锅炉负荷及蒸汽参数的前提下,炉膛内运行床温需控制在900~920℃之间。……