摘 要:目前CPⅢ轨道控制网(以下简称CPⅢ网)主要运用于高速铁路及客运专线,近年来,部分城市新建城市轨道交通(地铁)线路也逐渐推广应用CPⅢ网,从而使轨道施工精度得到了很大提升,同时对开通后的运营维护起到了关键指导作用。下面就城市轨道交通(地铁)线路CPⅢ网的应用情况进行简单分析总结。

关键词:CPⅢ轨道控制网;高程;平面;运营维护;轨道测量小车;轨道精测;长轨精调;变形监测

中图分类号:U239.5 文献标志码:A 文章编号:2095-2945(2018)30-0005-04

Abstract: At present, CPⅢ track control network (hereinafter referred to as CPⅢ network) is mainly used in high-speed railways and passenger dedicated lines. In recent years, some new urban rail transit (subway) lines in cities have gradually popularized and applied CPⅢ network. Thus the precision of the track construction has been greatly improved, and the operation and maintenance of the track has played a key guiding role. The following is a brief analysis of the application of CPⅢ network in urban rail transit (metro) lines, which is summarized as follows in the paper.

Keywords: CPⅢ track control network; elevation; plane; operation and maintenance; track survey trolley; track precision survey; long rail precision adjustment; deformation monitoring

1 CPⅢ网概念及应用意义

CPⅢ轨道控制网是指沿铁路(地铁)线路布设的平面和高程控制网,平面起闭于基础控制网(CPⅠ)或线路平面控制网(CPⅡ),高程起闭于线路水准基点,一般在线下施工完成并通过沉降变形评估后进行施测,为铁路(地铁)线路布轨道施工和运营维护的基准。

表1 CPⅢ桩间距布置原则

CPIII网为智能型全站仪自由测站边角交会的三维控制网(轨道平面坐标和绝对高程),其点间距为纵向30-60m左右一对控制点(CPⅢ桩间距布置原则见表1),点对的横向间距为10~20m,CPIII的精度要求很高,要求相邻点位的相对点位中误差≤1mm。因地铁隧道净空及曲线半径均较小,根据隧道断面结构图,在车站、矩形和马蹄形隧道等不同结构地段的布点方案有所不同(布点原则见图1和图2),控制点应高于轨面1.2~1.3m。CPIII测量组件主要构成有:预埋件、平面测量杆、高程测量杆、专用平面测量棱镜。CPⅢ桩应沿线路埋设在路基两侧接触网杆或其基础、桥梁防护墙、隧道边墙上、路肩上进行埋设。……