一种基于串扰理论的线缆护套屏蔽效能测试方法
2018-10-21宋世千
宋世千
摘要:设计了一种基于串扰理论的线缆护套屏蔽效能的测试方法,试验布置接近线缆护套的实际应用状态。根据测试结果分析了屏蔽护套不同接地方式对线缆间感性耦合、容性耦合的影响,试验结果可为在实际工程中抑制线缆串扰提供依据。
关键词:串扰;屏蔽效能;测试
Shielding Effectiveness Testing Method for
Shielding Sheath of Cables Based on Crosstalk Theory
SONG Shiqian
Abstract:A shielding effectiveness testing method based on crosstalk theory is designed for shielding sheath, which provides a measurement of sheath shielding effectiveness in real working conditions with more accuracy. The influence of different sheath grounding method on inductive coupling and capacitive coupling between cables is analyzed according to the test results. Testing and analysis of the conclusions provided the basis for the inhibition of the cable crosstalk in the actual engineering.
Key words:Crosstalk; Shielding effectiveness; Testing
引言
现有的大型机电设备上上,电气、电子设备及互联线缆种类繁多,工作电磁环境复杂,运行中会出现大量电磁干扰问题,对设备的正常运行造成潜在威胁。因此列车上的各设备均须严格的电磁兼容(EMC)认证。但实际工程中,一台独立进行EMC测试时合格的设备通过电缆连接后,工作时仍然会出现电磁干扰的问题,这是由于电缆在一定电磁环境下成为了高效的电磁波接收和辐射天线,同时也是干扰传导的良好通道[1]。为了抑制电缆对电磁波的接收和辐射,最常见的工艺是采用屏蔽护套进行包裹。这一工艺措施的有效性,往往通过对屏蔽护套材料的屏蔽效能测试,如窗口法测试[2][3]进行说明。但上述实验得到的是材料本身对电磁波屏蔽的性能,并不符合屏蔽护套的实际工作状态。因此设计本实验旨在测试线缆屏蔽护套在实际工作状况下的性能。
1 测试原理
采用屏蔽护套的目的一般是为了抑制线束、线缆之间的串扰。串扰被认为是两线间的感性耦合与容性耦合的叠加。对于低阻抗负载(高电流、低电压)感性耦合与容性耦合相比占主导地位;对于高阻抗负载(低电流、高电压)容性耦合与感性耦合相比占主导地位[4]。……