APP下载

核电站堆外中子噪声信号异常探析

2018-03-15罗婷胡建荣杨泰波简捷冯晋涛

科技视界 2018年1期

罗婷 胡建荣 杨泰波 简捷 冯晋涛

【摘 要】压水堆核电站堆内构件振动监测系统(Vibration monitoring system, VMS)通过分析堆外中子噪声信号,实现堆内构件振动情况的监测。在对中子噪声信号进行分析时,发现中子噪声信号出现了严重削波和电平异常问题。建议对信号通道进行排查检修,彻底解决中子噪声信号异常问题,为核电站的安全可靠运行提供保障。

【关键词】中子噪声信号;信号削波;电平异常;堆外核测系统

中图分类号: F426.23 文献标识码: A 文章编号: 2095-2457(2018)01-0141-002

【Abstract】Through the analysis of ex-core neutron noise signal by Vibration monitoring system, the monitoring of vibration condition of the reactor internals was realized. The serious signal clipping and abnormal level problems was found in the analysis of neutron noise signal. To completely solve the problems of neutron noise signal and provide guarantee for safe and reliable operation of nuclear power plant, the signal channel is recommended for troubleshooting and maintenance.

【Key words】Neutron noise signal;Signal clipping;Abnormal level;Ex-core nuclear test system

0 前言

压水堆核电站均配备有堆内构件振动监测系统(Vibration Monitoring System, VMS),该系统对堆外中子噪声信号进行分析,实现堆内构件振动情况的监测。堆内构件振动监测系统采集的中子噪声信号是来源于堆外核测系统8个中子探测器的信号。本文在对中子噪声信号进行分析来了解堆内构件振动情况的过程中,发现了堆外中子噪声信号出现了严重削波和电平异常的问题。

中子噪声信号削波和电平异常问题直接影响了堆内构件振动监测与分析,影响堆内构件振动情况的准确性判断,对核反应堆的安全运行不能提供可靠的保障。

本文发现堆外中子噪声信号的几点问题,建议对信号通道进行排查检修,解决中子噪声信号异常问题,为核电站的安全可靠运行提供保障。

1 核电站堆内构件振动监测系统中子噪声信号

VMS系统采集的中子噪声信号来源于堆外核测系统的8个中子探测器,其安装布置如图1所示。NB1、NB3、NB2、NB4通道信号为探测器第2段的中子噪声信号,径向间隔90o;……

登录APP查看全文