蒸汽发生器全部丧失给水事故分析及处理

2018-03-15徐海军

科技视界 2018年1期

徐海军

【摘 要】通过基于现实假设建立方家山核电厂的详细的计算模型,对完全丧失给水引发的事故进行分析。在APA和APD丧失后ASG启动失败,或者APA和APD一开始就不运行时ASG完全丧失的瞬态中,操纵员通过选择充排模式或者充溢模式,即通过建立安注向反应堆注水,同时开启稳压器排放管线来带走反应堆剩余功率,最终由EAS/RRI热交换器将热量带出安全壳,从而避免了堆芯熔化事故。长期阶段,安全注射停运及稳压器安全阀关闭,堆芯余热由RRA系统导出。但操纵员的动作必须在一定的时间限制之内实施,否则堆芯将裸露并熔化。

【关键词】全部丧失给水;充排模式;充溢模式

中图分类号: TL353.13 文献标识码: A 文章编号: 2095-2457(2018)01-0198-003

【Abstract】Based on the realistic assumption,a detailed calculation model of Fangshan nuclear power plant was established to analyze the complete loss of water supply induced accidents.After the ASG fails to be started after the APA and APD are lost or the ASG is completely lost at the outset of the APA and APD,the operator chooses to inject the water into the reactor by selecting either charge-fill mode or fill-up mode,The regulator discharge line takes away the remaining reactor power and eventually the heat is taken out of the containment by the EAS/RRI heat exchanger, avoiding core melting.In the long term,the safety injection shut-down and regulator safety valve are closed and the core waste heat is exported by the RRA system.However,the operator's actions must be carried out within a certain time limit,otherwise the core will be exposed and melted.

【Key words】All lost water;Filling mode;Overflow mode

在壓水堆核电站中,虽然发生堆芯熔化事故的概率远远低于设计基准事故,但是严重事故的潜在风险及其发生后对公众安全和环境的威胁相当大。因此,必须对严重事故进行深入、全面地研究,制定严重事故的管理规程。1979年美国三里岛核电站发生堆芯熔化事故后,严重事故的研究受到了广泛重视。本文通过对完全丧失给水事故采用现实假设,采用更为真实合理的系统运行值和保护定值,对事故瞬态和后续操纵员动作进行了详细的分析,从而对全部丧失给水后堆芯状态及进程有了更深层次的了解,为操纵员在事故后操作提供指导。

1 事故概述

1.1 事故定义

蒸汽发生器给水完全丧失表现为:正常给水(ARE)丧失,或启动给水系统(APD)丧失,随后辅助给水系统(ASG)未能启动;……