广播发射台站天线交换控制系统控制原理浅析
2018-03-01周艳坤
周艳坤
【摘 要】代播机是广播发射台站里安全播出的一个重要保障,可有效的缩短发射机停播时间,代播机在使用时需要经过交换开关上主播机天线,因此设计一套稳定可靠控制交换开关的系统极为重要。本文从硬件的控制原理和软件方面对交换控制系统进行了浅析。
【关键词】交换开关;变频器;控制系统;软件
中图分类号: TN827.1 文献标识码: A 文章编号: 2095-2457(2018)36-0266-002
DOI:10.19694/j.cnki.issn2095-2457.2018.36.114
Analysis on the Control Principle of Antenna Exchange Control System at Broadcast Station
ZHOU Yan-kun
(State Administration of Press, Publication, Radio, Film and Television 594 Station ,Shanxi Xianyang 712000, China)
【Abstract】Backup broadcast transmitter is an important guarantee for the safe broadcasting of broadcast stations. It can shorten the time of the break of principal broadcast transmitter. When the backup broadcaster transmitter act as a substitute for the principal broadcaster, It needs to connect with the antenna of the principal broadcast transmitter through the exchange switch. Therefore, it is extremely important to design a stable and reliable control exchange switch system. This paper analyzes the exchange control system from the aspect of hardware control principle and software.
【Key words】Exchange switch; Frequency converter; Control system; Software
1 交換开关的控制原理
交换开关是在广播发射电台普遍使用的一种切换开关,开关内的刀体驱动是通过三相异步电机经过二级变速后通过槽轮机构带动主轴,主轴带动刀体转动,在开关内的触点之间切换来完成通路的切换。交换开关里一般有两组接点。我们需要完成的工作是控制交换开关的两组接点之间来回切换。通过对三相异步电机转向的控制,即可实现对交换开关位置的控制。在交换开关的底部安装有微动开关,这个微动开关有两个端子,是交换开关两组触点到位信号采样端子。
变频器应用变频技术和微电子技术,改变电机的工作电源频率来控制交流电动机,变频器主要由整流、滤波、逆变器、控制器等几部分组成。整流是将工作频率固定的交流电机转换为直流电;整流后的直流电压中,含有电源倍频的脉动电压,并且逆变器产生的脉冲电流也使直流电压变动,为了抑制电压波动所以采用电感和电容组成的滤波电路来吸收脉动电压;逆变器的主要作用是将直流电转化成不同频率、宽度、幅度的方波;……