全球定位系统跟踪足球运动员跑动距离的准确性实验

2018-02-03刘鸿优唐小明陈彦龙

体育学刊 2018年1期
关键词:设备实验

刘鸿优 唐小明 陈彦龙

摘 要:通过实验测试的方法,对可穿戴全球定位系统(GPS Catapult Optimeye S5)在跟踪足球运动员的跑动距离的信效度进行检验。选取10名大学生足球运动员为实验对象,分别以不同的速度完成了8组60 m直线跑、50 m转弯直线跑和40 m “Z字型”折线跑。GPS跟踪到的每名实验对象每种测试的跑动距离分别为(57.65±2.76)、(46.19±4.09)和(36.50±2.59) m。GPS在跟踪60 m直线跑时,实验对象的测试平均次间CV为0.03(0.01~0.05),平均次间SE为0.61(0.25~1.06),平均Bias为4.9%(1.8%~10.7%),平均SEE为2.4%(1.8%~3.0%);在跟踪50 m转弯直线跑时,平均次间CV为0.06(0.04~0.11),平均次间SE为1.05(0.63~1.76),平均Bias为8.4%(3.1%~17.3%),平均SEE为4.9%(2.2%~10.3%);在40 m “Z字型”折線跑时,平均次间CV为0.06(0.03~0.11),平均次间SE为0.79(0.42~1.51) ,平均Bias为9.5%(3.8%~14.4%),平均SEE为4.6%(3.0%~5.7%)。实验结果证明GPS Catapult Optimeye S5装备在跟踪足球运动员的跑动距离时具备足够的准确性,跟踪到的运动员移动数据拥有足够的信效度用于科研与教练指导用途。

关 键 词:竞赛与训练;运动监控;足球;跑动距离;全球定位系统

中图分类号:G843 文献标志码:A 文章编号:1006-7116(2018)01-0132-05

Abstract: By means of experimental test method, the authors verified the reliability and validity of Catapult Optimeye S5, a wearable global positioning system, tracking football players running distances. The authors selected 10 university students as experiment objects, who completed 8 rounds of 60m straight line running, 50m turning straight line running and 40m Z-shape fold line running at different speeds. As tracked by the GPS, the experiment objects running distances in the tests were (57.65±2.76)m, (46.19±4.09)m and (36.50±2.59)m respectively. When the GPS tracked 60m straight line running, the experiment objects average within-player CV was 0.03 (0.01~0.05), their average within-player SE was 0.61 (between 0.25 and 1.06), their average Bias was 4.9% (1.8%~10.7%), their average SEE was 2.4% (between 1.8% and 3.0%); when the GPS tracked 50m turning straight line running,, the experiment objects average within-player CV was 0.06 (0.04 ~0.11), their average within-player SE was 1.05 (between 0.63 and 1.76), their average Bias was 8.4% (between 3.1% and 17.3%), their average SEE was 4.9% (between 2.2 and 10.3%); when the GPS tracked 40m Z-shape fold line running,, the experiment objects average within-player CV was 0.06 (between 0.03 and 0.11), their average within-player SE was 0.79 (between 0.42 and 1.51), their average Bias was 9.5% (between 3.8% and 14.4%), their average SEE was 4.6% (between 3.0% and 5.7%). The experiment results prove that the GPS Catapult Optimeye S5 equipment is provided with adequate accuracy when it tracks football players running distances, and the players moving data it tracks have adequate reliability and validity for the purposes of scientific research and coach guidance.

Key words: competition and training;sports monitoring;football;running distance;global positioning systemendprint

可穿戴的全球定位系统(Global Positioning System,GPS)可以跟踪运动员在训练和比赛中的移动距离、移动轨迹、移动速度和加速度等外部运动负荷变量,因而越来越受到运动队、教练员和科研人员的青睐[1]。

最早专门运用于团体运动表现监控的GPS出现在2003年[2],为澳大利亚GPSports公司生产的GPSports Systems SPI-10,随后几年,该公司陆续改进并生产了SPI-Pro、WiSPI和SPIElite等版本。2006年,澳大利亚公司Catapult Innovation陆续推出了Catapult Minimax系列和Catapult Optimeye系列可穿戴GPS设备。Catapult公司生产的可穿戴GPS设备能提供更多的运动表现变量和更精确的算法,从而超越GPSports,成为了体育运动表现监控专用GPS设备生产领域的主要供应商。

值得注意的是,要将可穿戴GPS设备运用于指导训练和科学研究,必須先对该设备跟踪获得的数据准确性和信效度进行验证,只有在数据足够准确的情况下,才能保证该设备的应用价值[3-4]。……