APP下载

核电汽轮机瓦振探头闪发故障原因分析与处理

2018-01-28张小辉沈超吕凯

中小企业管理与科技·中旬刊 2018年11期

张小辉 沈超 吕凯

【摘 要】论文针对核电项目汽轮机在调试启动过程中多次闪发瓦振探头故障报警问题,通过瓦振探头工作原理、信号干扰源、通道传输过程、差异性等全面分析,提出汽轮机瓦振探头故障闪发引发跳机风险的控制措施和问题处理方案,解决了汽轮机瓦振探头闪发的问题,降低了汽轮机跳机风险。

【Abstract】In view of the frequent failure alarm of the flash fault of the vibration probe in the process of debugging steam turbine of a nuclear power project, the paper comprehensively analyzes the working principle of watt-vibratory probe, signal interference source, channel transmission process and difference. It puts forward the control measures and problem solving scheme of the risk of jumping machine caused by the fault flash of turbine tile vibration probe, which can solve the problem of flicker of turbine tile probe, and reduce the jump risk of the turbine.

【關键词】瓦振探头;故障闪发;信号干扰

【Keywords】 tile vibration probe; fault flash; signal interference

【中图分类号】TK268 【文献标志码】A 【文章编号】1673-1069(2018)11-0179-02

1 引言

2018年5月24日,某电厂5号机执行完电源切换试验后机组处于跳堆、跳机状态。当日下午,在机组再次冲并前,现场巡检查询控制系统画面及报警日志,发现5号机汽轮机1~6瓦共12个瓦振探头在5月24 下午13:04:33 同时闪发瓦振探头故障信号约0.6s,1~6瓦瓦振均触发2取2故障跳机保护信号。在该时间段1~6瓦瓦振测量数值稳定正常,其他轴系振动、温度测量数据也无异常,现场确认报警触发前后在汽轮发电机及轴承箱处均无相关工作。

5号机采用的是西门子百万千瓦机组,汽轮机安全监视系统(GME)使用的是Vibro生产的TSI传感器,其中瓦振探头使用的是压电式加速度传感器CA202,压电加速度计通过内部敏感芯片输出一个与加速度成正比的电荷信号,通过电荷信号调理器IPC704将接收到的电荷信号放大转换成偏置12mA的交流uA信号。传感器和前置器通过带屏蔽的延伸电缆连接,这段信号由于是电荷信号,抗干扰能力比较弱。汽轮机瓦振探头闪发故障已在多台机组出现,而且根据西门子逻辑图设计同瓦的两个瓦振探头同时闪发故障,汽轮机直接保护跳机。……