An Improved Method for Noninvasive Detection of Blood Glucose of Conservation of Energy Metabolism*
2016-09-09ZHANGYangCHENZhenchengZHUJianmingXUBiaoSchoolofElectronicEngineerandAutomaticGuilinUniversityofElectronicTechnologyGuilinGuangxi54004ChinaSchoolofLifeandEnvironmentalSciencesGuilinUniversityofElectronicTechnologyGuilinGu
ZHANG Yang,CHEN Zhencheng,ZHU Jianming,XU Biao(.School of Electronic Engineer and Automatic,Guilin University of Electronic Technology,Guilin Guangxi 54004,China;.School of Life and Environmental Sciences,Guilin University of Electronic Technology,Guilin Guangxi 54004,China)
An Improved Method for Noninvasive Detection of Blood Glucose of Conservation of Energy Metabolism*
ZHANG Yang1,CHEN Zhencheng2*,ZHU Jianming2,XU Biao1
(1.School of Electronic Engineer and Automatic,Guilin University of Electronic Technology,Guilin Guangxi 541004,China;2.School of Life and Environmental Sciences,Guilin University of Electronic Technology,Guilin Guangxi 541004,China)
In order to improve the accuracy of non-invasive blood glucose measurement based on the method of con⁃servation of energy metabolism.The sensor for non-invasive blood glucose measurement was designed,300 groups of clinical trial data were collected.This paper put forward DE-PLS algorithmthe which combine decision tree and partial least squares method to handle data to establish forecast model of blood glucose values.The results of multi parameter correlation analysis show that the metabolic rate was significantly associated with the true values of the blood glucose,verified the correctness of non-invasive blood glucose measurement which based on the theory of con⁃servation of energy metabolism.The final results indicated the correlation between the test values calculated by the DE-PLS algorithm and the true values of the blood glucose reached 88.5%.Confirmed the accuracy of this algorithm is higher than other algorithms applied in this field.
noninvasive blood glucose detection;the law of conservation of energy metabolism;sensor design;the decision tree;partial least squares
糖尿病是胰岛素分泌失调导致血糖偏离正常范围引起身体异常的疾病[1]。微创血糖检测和生化血糖检测是现阶段主流的检测手段[2],技术也相对成熟、精确度也高。无创血糖检测是血糖仪的发展方向,会给糖尿病管理带来便利,能给糖尿病的预防、治疗、血糖值的控制提供依据,为糖尿病患者带来福利。无创检测[3-4]血糖研究方向包括辐射和光学方法;人体组织液提取法;代谢热整合法;阻抗谱法。近红外技术是目前研究方向的主流,但是在临床试验中,不同个体的成分含量和生理状况有异,形成不可消除的误差。本文采用基于热代谢整合法的能量代谢守恒法[5-8]来进行无创血糖检测的研究。设计出新型无创血糖检测探头[9],并在前人研究基础上[10]提出一种新算法[11-13]处理数据,建立预测血糖值的模型,与微创血糖检测方法检测的血糖真值相关性[14-16]提升到88.5%,高于应用于该领域的其他算法。
1 检测原理
1.1能量代谢守恒法
日本Ok Kyung Cho等人研究出了热代谢整合模型[17],在此模型基础上建立能量代谢守恒法。由能量代谢守恒法可得人体产热量与血糖、代谢率、血液流速和血氧相关。根据原理可以推导出能量代谢守恒法数学模型为:

式中BG为血糖浓度(Blood Glucose);HR为心率;H为代谢产热量;Bv为血流速度;SPO2为血氧饱和度;ξ为算法修正因子。
将公式移项得到血糖的数学描述公式,如式(2):

1.2人体代谢产热量检测
本文提出了一种新的代谢率的检测方法,正常情况下人体体温保持在一定范围内,人体产热与蒸发、传导、对流、辐射等所散失的热量总合是相等的。……
杂志排行
传感技术学报的其它文章
- Fabrication and Application of Micro Piezoelectric Composite Ultrasonic Detector*
- Gas Concentration Dynamic Prediction Method of Mixtures Kernels LSSVM Based on ACPSO and PSR*
- The Design and Implementation for Three Dimension Co-Vibrating Vector Hydrophone*
- Research on Algorithm of Piezo-Film Vehicle Weigh-in-Motion System*
- Energy Balanced and Fault Tolerant Data Gathering Algorithmfor Heterogeneous Wireless Sensor Network*
- An Improved Trust Evaluation Model Based on Bayesian for WSNs*