APP下载

胎心监护与脐血流检测在胎儿窘迫预测中的应用

2016-05-14余云志

中外医疗 2016年7期
关键词:检测方法

余云志

[摘要] 目的 分析胎心监护以及脐血流检测方法应用于胎儿窘迫预测工作中发挥的作用。方法 随机选择2014年7月—2015年7月该院190例胎儿窘迫患者,针对患者进行胎心无负荷试验(NST)的同时对其脐血流(S/D)比值进行科学测定,对所有研究对象临床状况进行实时观察。结果 S /D比值小于3的有178例,反应型占72.72%,可疑型占22.11%,无反应型占5.15%;S /D比值大于等于3的有11例,其中反应型占9.09%,可疑型占45.45%,无反应型45.45%。S /D<3以及S /D≥3在NST反应型以及无反应型对比中差异有统计学意义(P<0.01)。S /D≥3在反应型及可疑型发生率方面明显高于无反应型,胎心监护与脐血流检测方法在异常结果方面存在密切关系(P<0.01),两种检测方法在结果方面差异有统计学意义(P<0.01)。结论 针对胎儿窘迫,同时选择胎心监护与脐血流检测方法进行联合诊断,可以提高临床诊断的准确性和科学性,对胎儿预后情况进行改善,促使围产儿病死情况大大减少。

[Abstract] Objective To analyze the function of fetal electrical monitor and umbilical blood flow detection method in the fetal distress prediction. Methods 190 cases with fetal distress treated in our hospital from July 2014 to July 2015 were selected and given non-stress test(NST), at the same time, their umbilical artery blood flow (S/D)ratios were given scientific measure, the clinical status of all the research object were given real-time observation. Results There were 178 cases whose S /D ratio <3 with reaction type accounting for 72.72%, suspicious type accounting for 22.11% and non-reaction type accounting for 5.15%, there were 11 cases whose S /D ratio ≥3 with reaction type accounting for 9.09%, suspicious type accounting for 45.45% and non-reaction type accounting for 45.45%, there was an obvious difference between the cases whose S /D<3 and S /D≥3 in the reaction type and non-reaction type in the NST(P<0.01), the incidence of S /D≥3 in the reaction type and suspicious type was obviously higher than that in the non-reaction type, there was a close relationship in the abnormal results between the fetal electrical monitor and umbilical blood flow detection method(P<0.01), and there was an obvious difference in the results between the two detection methods. Conclusion The combined diagnosis of fetal electrical monitor and umbilical blood flow detection method can improve the accuracy and scientificity of the clinical diagnosis, improve the fetal prognosis and promote the decrease of perinatal mortality.

[Key words] Fetal electrical monitor; Umbilical blood flow detection; Fetal distress; Clinical prediction

脐血流检测属于临床上对于围产儿的一种有效监护途径,能够对胎儿窘迫发挥良好的预测效果,并有效改善新生儿预后状况[1]。为了分析胎心监护以及脐血流检测方法应用于胎儿窘迫预测工作中发挥的作用,为今后的胎儿窘迫预测工作提供科学的参考依据,该研究随机选择2014年7月—2015年7月该院190例胎儿窘迫患者,针对患者进行胎心无负荷试验(NST)的同时对其脐血流(S/D)比值进行科学测定,对所有研究对象临床状况进行实时观察,现报道如下。

1 资料与方法

1.1 一般资料

选择随机2014年7月—2015年7月该院190例胎儿窘迫患者纳入该研究样本。190例研究对象中年龄下限22岁,年龄上限33岁,患者平均年龄(28.8±5.2)岁。该研究中属于初产妇的有145例,其余45例属于经产妇,所有患者均属于单胎妊娠。该研究中患者孕周最短的有37周,孕周最长的有42周,平均孕周(39.2±4.3)周患者均没有进入产程,其胎膜均没有发生破碎。该研究对象中属于正常妊娠的有153例,其余37例属于高危妊娠。

1.2 方法

借助东莞市健威医疗器械有限公司生……

登录APP查看全文

猜你喜欢

检测方法
学习方法
小波变换在PCB缺陷检测中的应用
用对方法才能瘦
四大方法 教你不再“坐以待病”!
赚钱方法
捕鱼