配置HRB500钢筋小跨高比带板开缝连梁的抗震性能试验研究
2016-04-06刘瑞欣王敏陈晓磊朱文博傅剑平
刘瑞欣 王敏 陈晓磊 朱文博 傅剑平
摘要:为了防止联肢剪力墙中小跨高比连梁发生低延性剪切破坏,在单连梁中部设置一条通缝,形成开缝连梁改善其抗震性能。试验完成了3个小跨高比带板开缝连梁的低周反复加载,通过与其他配筋形式连梁对比,分析了开缝连梁的破坏形态、滞回特征、承载力退化、刚度退化、延性、耗能等一系列抗震性能。利用软件ABAQUS对试件滞回曲线的骨架曲线进行模拟,并将模拟结果和试验结果相对比。结果表明,小跨高比开缝连梁具有良好的承载能力及变形能力,施工较为方便且经济,能有效防止小跨高比连梁延性较差的剪切破坏,具有较好的抗震性能,可在实际工程中推广。
关键词:开缝连梁;小跨高比连梁;带板;抗震性能;钢筋
中图分类号:TU375.1
文献标志码:A文章编号:16744764(2016)01000908
Abstract:
Smallspantodepthratio coupling beams of shear wall can be formed with a crack in the middle to prevent from shear failure and improve the seismic performance. Three coupling beams with same smallspantodepthratio were tested under cyclic loading. Comparing the results of slotted coupling beams with other coupling beams of different forms of reinforcement, we analyzed the seismic behavior of the slotted coupling beam, including failure pattern, hysteresis loop, strength degradation, stiffness degradation, ductility and energy dissipation. We simulated skeleton curve of specimens hysteresis curve by using ABAQUS and compared the simulation result mith the experiment result. The results show that slotted coupling beams with smallspantodepthratio have good performance of bearing capacity and deformation.They can be constructed conveniently and economically. Besides, with the good seismic performance, smallspantodepthratio coupling beams could prevent from shear failure effectively and be applied well in practical engineering.
Keywords:slotted coupling beam; smallspantodepthratio; slab; seismic performance;bar
在剪力墙结构、框架剪力墙结构、框架核心筒结构中,常出现小跨高比连梁。众所周知,连梁作为联肢墙的第一道抗震设防防线,应具有良好的变形耗能能力,然而小跨高比连梁延性较差,容易发生剪切破坏。因此,对连梁的设计至关重要。学者们根据小跨高比连梁的特征采用了不同的配筋方案。Paula等[1]提出了在小跨高比连梁内加设对角暗撑的配筋方案,Tegos等[2]提出了菱形配筋方案,文献[34]提出了复合斜配筋方案。以上配筋改进方案虽然不同程度地改进了连梁的抗震性能,但也加大了施工难度,由于钢筋配置较拥挤,骨架需要相互贯穿,难以保证混凝土浇筑质量。……