复卷机直流传动电气控制系统的
2016-01-20李天利
·复卷机·
复卷机直流传动电气控制系统的
故障分析和解决办法
李天利
(陕西科技大学, 陕西西安, 710021)
摘要:针对由可编程序控制器、直流装置、通信总线组成的复卷机电气控制系统,从控制系统的原理出发分析了每个部分常见故障的现象、可能原因以及排除故障的方法。实践表明,只要有效掌握各种电气故障的现象、原因和排除方法,就能快速有效地排除故障,使复卷机恢复正常生产。
关键词:复卷机;故障分析;解决办法
作者简介:李天利先生,副教授;主要研究方向:电力电子技术及其应用。
中图分类号:TS755.9
文献标识码:A
文章编号:0254- 508X(2015)06- 0041- 04
收稿日期:2015- 02- 12(修改稿)
Abstract:Aiming at the rewinder electric control system consisting of programmable logic controller, DC device and communication bus, the common faults of each section, the possible causes and their troubleshooting methods were analyzed based on the principle of electric control system. It was proved that as long as the various common faults and their possible causes were effective by mastered, the faulted rewinder could be quickly repaired and recovered its normal operation.
The Fault Analysis and Its Solution of Control System of the Rewinder Driving by Direct Current
LI Tian-li
(ShaanxiUniversityofScience&Technology,Xi′an,ShaanxiProvince, 710021)
(E-mail: litianli@sust.edu.cn)
Key words:rewinder; fault analysis; solution
国产复卷机的电气控制大多由PLC(可编程序控制器)、直流装置、通信总线组成。这些设备出现故障时,都会造成复卷机故障而影响正常生产。但是这些设备故障的现象表现不一、原因复杂多样,情况不尽相同,因此解决的方法应从实际出发,具体问题具体分析。
1PLC故障分析和解决办法
1.1输出不工作
当被控制的设备发生了故障(如电磁阀损坏等)、接线错误或松动、输出过载等都可能使PLC的输出不能正常工作,如当抱闸电机出现异常或损坏,虽然PLC正常但也不能正常抱闸。这类故障可分段排除:先检查PLC的输出是否符合要求、再查对应的控制设备是否正常。
1.2系统故障指示灯亮
当PLC受到干扰、用户程序错误或PLC本身的元件损坏都可能使PLC的系统故障指示灯发亮。若属于用户程序错误和PLC本身的元件损坏可依据PLC的故障代码排除,但干扰是常见的也是较为麻烦的一个问题,现对其进行分析,以供参考。……