摘 要:采用火焰原子吸收分光光度计测定了纯化水中硒的含量。实验优化了仪器测量参数,分别考察燃烧器温度、燃烧器的高度、元素灵敏线、灯电流、火焰及狭缝宽度等对测定的影响。结果: 仪器检出限为0.004 5 μg/L,样品的吸光度为0.169,水样中硒平均含量为6.68 μg/L,标准偏差为0.015 3。样品的测得结果(6.68±0.015 3) μg/L,样品曲线回归线y=0.0256x+0.171,r=0.998。结论:火焰原子法操作简便、灵敏度高,适合快速测定水中的微量硒。
关 键 词:火焰原子吸收分光光度计; 硒; 纯化水
中图分类号:O 657 文献标识码: A 文章编号: 1671-0460(2015)06-1432-03
Determination of Se in Water by Flame Atomic Absorption Specrophotometer
KE Cheng-you, ZHU Kong-ru, ZHANG Yi
(Shenyang University of Chemical Technology,Liaoning Shenyang 110142,China)
Abstract: The flame atomic absorption spectrophotometer was used to determine the total selenium content in water. The instrument survey parameters in the experiment were optimized, effect of burner temperature, burner height, element line sensitivity, lamp current, flamboyance and slit width on the determination was investigated. The results show that the detection limit is 0.004 5 μg/L, sample absorbance is 0.169, the average content of Se is 6.68 μg/L, sample standard deviation is 0.0153, the measurement results are 6.68±0.015 3 μg/L, the sample regression line y=0.0256x+0.171, r=0.998. So the experimental technique operation is simple, the sensitivity is high, the result is satisfying.
Key words: Flame atomic absorption spectrophotometer;Selenium;Purified water
硒是人体必需的微量元素之一,通过生物的地球化学营养链给人以影响[1]。其与机体的抗氧化能力、免疫功能、抗癌作用等有着重要的关系[2]。当硒缺乏的时候,就很容易导致人体免疫能力下降,威胁人类健康。生命的四十多种疾病都与人体缺硒有关,如癌症、心血管病、肝病、白内障、胰脏疾病、糖尿病、生殖系统疾病等症状[3]。硒还可以与其他的一些重金属元素有拮抗作用[4],所以食用富硒食品既可以增强体质,达到预防疾病的目的,还可以预防人体重金属元素中毒[5]。
硒是人体必需的微量元素,但是摄入过多对人体健康造成危害[6]。近年来,在食品加工方面有任意在一些食品中强化硒的倾向[7,8]。为了保障人体健康,必须加强硒在食品、水中含量的监测力度[9]。
本文以水为研究对象,用火焰原子吸收法来测定水中的硒元素[10,11]。同时为了测定准确可靠,也考察了其他元素干扰程度。通过实验的预处理,把水进行消解,这样有利于火焰原子吸收法的测定[12]。……