离子色谱法检测锅炉炉水换热器泄漏的分析方法的建立
2015-10-21赵晶晶吴雪
赵晶晶 吴雪



摘 要:换热器泄漏对生产的危害较大。通过对锅炉给水换热器工艺及介质的分析,建立了一种新的监测换热器泄漏的分析方法:离子色谱法。该方法以换热器前后工艺冷凝液中的Na+和PO43-的变化成功预测了海油建滔锅炉给水换热器的泄漏。为以高压水和低压气为介质的换热器的监控提供了分析依据。
关 键 词:离子色谱法;换热器;泄漏
中图分类号:O 657 文献标识码: A 文章编号: 1671-0460(2015)06-1425-03
Establishment of A New Analysis Method for Monitoring the Leakage of the Boiler Feed Water Heat Exchanger by Ion Chromatography
ZHAO Jing-jing,WU Xue
(China Blue Chemical Corporation, Hainan Dongfang 572600,China)
Abstract: Leakage of heat exchanger has great harm on the production. In this paper, through analysis of technology and media, a new analysis method named ion chromatography for monitoring heat exchanger leakage was established. This method is based on the change of Na+ and PO43- in the process condensate. It has successfully predicted the leakage of CNOOC-KB boiler feed water heat exchanger. The new method provides accurate data for monitoring heat exchanger with high pressure water and low pressure gas as medium.
Key words: Ion chromatography; Exchanger; Leakage
换热器作为化工装置常用的设备,在装置正常运行过程中,换热器泄漏是经常遇到的现象。目前,由于各种原因产生的换热器泄漏,造成的物料损失和环境污染[1-4],既影响生产装置的正常运行,还严重影响工厂的经济效益,如何监测换热器的泄漏已成为生产中不可忽视的问题[5-7]。2014年3月以来,中海石油建滔化工有限公司60万t吨甲醇装置E01005高压锅炉给水预热器的工艺参数有微小的变化,怀疑换热器内部发生泄漏,但是工艺参数的变化无法给出准确的答案。因此需要针对该换热器的工艺及介质建立了相应的分析方法。常用分析方法是采用比色法对换热器前后的工艺冷凝液中的PO43-的浓度进行分析。但是该种方法存在准确度低、误差大的缺点。同时由于操作人员对消解终点判断存在差异导致分析结果的平行性也较差,无法对工艺提供准确的分析数据。针对该种分析方法存在的缺陷,本文建立了一种新的分析方法:离子色谱法。该种方法不仅能够准确测定工艺冷凝液中的微量的PO43-的浓度,也能够准确测定工艺冷凝液中微量Na+的浓度。……