管道阴极保护设计、施工与测试
2015-10-21王桂英任佩佳庄严
王桂英 任佩佳 庄严


摘 要:为了确保管道长周期、安全稳定地运行,文章从设计、施工及测试等方面介绍了成品油管道工程阴极保护及航空煤油管道工程阴极保护,并采用外加电流与牺牲阳极联合方式对管道进行保护,以提高管道安全运行。
关 键 词:阴极保护;参数;选址;安装;连接;调试;检测
中图分类号:TE 832 文献标识码: M 文章编号: 1671-0460(2015)06-1327-03
Design, Construction and Test of Pipeline Cathodic Protection
WANG Gui-ying,REN Pei-jia,ZHUANG yan
(HQC Liaoning Company, Liaoning Fushun 113006, China)
Abstract: In order to keep the pipelines operating safely and steadily, cathodic protection applied in petroleum products pipeline project and aviation kerosene pipeline project was introduced from the aspects of design, construction and test. And its pointed out that combination of impressed current and sacrificial anode should be used to protect the pipeline.
Key words: Cathodic protection; Parameter; site selection; Installation; Connection; Debugging; Detection
1 概 述
某公司成品油管道工程陰极保护及航空煤油管道阴极保护工程。
1.1 成品油管道阴极保护
(1) 成品油管道全长243.5 km。
(2) 成品油管道主要采用Ф355.6及Ф377
钢管,埋深(地表至管顶)大约在1.5 m左右,钢管外壁大都采用沥青玻璃布加强级防腐,部分管段采用TO树脂玻璃布加强级防腐,管道途中多次穿越公路、铁路、河流等。
(3) 沿线土壤电阻率一般在20~30 Ω·m,高的电阻率大于100 Ω·m。
(4) 冻土层一般为1 m。
1.2 航空煤油管道阴极保护
(1)航空煤油管道全长42 km。
(2)航空煤油管道外壁防腐与成品油管道相同。
2 管道阴极保护方式
综合考虑电源供应、施工造价、杂散电流、涂层施工质量等诸多因数,管道采用外加电流与牺牲阳极联合保护方案。其中在成品油与航空煤油管道通沟铺设段,采用外加电流与牺牲阳极共同保护方案,在其它管段则视情况,或者采用外加电流保护方案,或者采用牺牲阳极保护方案。
为了避免阴极保护电流流入站场,首、末站及中间泵站均加设绝缘法兰。
在牺牲阳极与外加电流保护段之间也加有绝缘法兰。
3 阴极保护参数
3.1 外加电流阴极保护
(1) 最小保护电位:Emin=-0.85 V(相对铜饱和硫酸铜参比电极)[1]。……