质量流量计量误差分析与对策
2015-10-21汪楚尧
汪楚尧



摘 要:油品计量分为静态计量与动态计量。静态计量是最早采用的计量方式,它具有通用、直接、投资少的特点,但也存在诸多的不确定因素,如:人员、温度、密度、体积、取样等环节。近些年来,随着石油行业计量水平的提高以及市场竞争不断加剧,计量准确度越来越受到各企业的重视,动态计量更为符合石化行业的需求,它多以质量测量进行交接计量,直接测量油品的质量,避免了不必要的测量因素,提高了测量的准确度。
关 键 词:动态计量;质量测量;准确度
中图分类号:TQ 018 文献标识码: A 文章编号: 1671-0460(2015)06-1312-04
Analysis and Countermeasures of Mass Flow Measurement Error
WANG Chu-yao
(PetroChina Fushun Petrochemical Company, Liaoning Fushun 113008,China)
Abstract: Oil metering is divided into static measurement and dynamic measurement. The static measurement is the earliest measurement method, it is universal, direct, less investment, but there are many uncertain factors, such as temperature, density, and volume, sampling etc. In recent years, along with improvement of the measurement level in the petroleum industry, the measurement accuracy is more and more important to enterprises, dynamic measurement is more in line with the needs of the petrochemical industry, it uses mass measurement to carry out custody transfer metering, direct measurement of mass can avoid needless measurement factors, and can improve the measurement accuracy.
Key words: Dynamic measurement; Mass measurement; Accuracy
质量流量计发展于上世纪70年代,在世界范围内,它属于动态计量的一种重要手段,在石油化工行业的贸易结算中,质量流量计发挥着举足轻重的作用,它的测量误差不仅直接影响着企业的经济效益,也担负着监督各类生产装置物料供需之间的平衡关系。然而在实际使用过程中,由于其本身结构、工作原理及工况条件不为大家所熟悉,经常会造成计量失准的问题,给企业的经济效益及平稳生产带来了风险。本人长期以来在质量流量计检定、维护及使用过程中总结了一些經验,在此与大家分享。
1 工作原理
简单点说,质量流量计(以下简称“流量计”)由传感器和变送器两部分组成。
传感器是基于科里奥利力(科里奥利1792年至1843年,法国数学家、气象物理学家)效应的相位敏感型谐振式传感器。为描述旋转体系的运动,需要在运动方程中引入一个假想的力,这就是科里奥利力。……