二级水解(酸化)的优化
2012-10-19李鹏飞
李鹏飞
[摘要]在实际的工业废水处理工程中,作为生化预处理单元的水解(酸化),不但降低了废水的 COD Cr 值,而且提高了废水的可生化性。本文论述了水解(酸化)反应的特点及原理;介绍了水解(酸化)反应器在工程应用中的效果;总结了影响水解(酸化)反应器运行的主要因素,以及运行和改造方案。
[关键词]水解(酸化); 厌氧污泥培养; 工程应用
[Abstract] in actual industrial waste processing project, as the hydrolisis of biochemical pretreatment unit (acidification), not only reduced the COD Cr value of waste water, moreover enhanced the bio-chemical capability of waste water. This article elaborated the hydrolisis (acidification) the characteristics and principle of response; Introduced the hydrolisis (acidification) the effect of reactor in application; Summarizes primary factor that influence hydrolisis (acidification) reactor moved, as well as movement and transformation plan.
[Keywords] hydrolysis (acidification), anaerobic sludge engineering application
中图分类号:TQ09文献标识码:A
厌氧处理技术是一种有效矿化有机物的微生物处理技术,在一定条件下,厌氧细菌能将有机物转化为 CH 4 及 CO 2 等气体(俗称沼气)。相对于好氧处理技术而言,其具有剩余污泥少、运行费用低及回收能源等优点,本人长期的生产实践证明:厌氧消化过程中的水解(酸化)段不但能降低 COD Cr ,同时还可以提高废水的可生化性。
调整前情况
经理论分析与长期的水质跟踪研究表明:二级水解酸化单元对CODcr去除率最高才10%未达设计要求有优化运行的潜力。
运行数据表明,二级水解酸化去除COD作用不明显,很多时候只起到对 CAST 出水悬浮污泥的截留作用;根据污水处理场装置标定分析数据记录,二级水解酸化段DO在4-8mg/L之间,可见二级水解酸化没有起到厌氧水解酸化作用,而是进入了好氧阶段。
调整项目
1、酸碱度( PH 值)
根据各类型废水处理工程经验,水解(酸化)反应器对 PH 值变化的适应性较强。废水的 PH 值在 5 ~ 10 之间,水解(酸化)均能正常运行。但当 PH 值〈 5或〉10 时,水解(酸化)反应器的出水效果变差,且影响到后续工序的处理,导致系统的最佳出水往往不达标。……