锅炉炉膛安全监控系统的理论分析及防止爆燃的措施
2012-04-10王书浩
王书浩
摘要:FSSS系统功能 FSSS系统一般分为两个部分,即燃烧器控制系统BCS(Burner ControlSystem)和燃料安全系统FSS(Fuel Safety System)。燃烧器控制系统的功能是对锅炉燃烧系统设备进行监视和控制,保证点火器,油枪和磨煤机组系统的安全启动、停止和运行。燃料安全系统的功能是在锅炉点火前和跳闸停炉后对炉膛进行吹扫,防止可燃物在炉膛堆积。在检测到危及设备、人身安全的运行工况时,启动主燃料跳闸(MFT),迅速切断燃料,紧急停炉。
关键词:FSSS、主燃料跳闸、锅炉炉膛燃爆、防止燃爆
Abstract: the FSSS System function FSSS System generally divided into two parts, namely the Burner BCS control System (Burner ControlSystem) and Fuel security System FSS (Fuel Safety System). The burner is the function of control system for boiler combustion system monitoring and control equipment, ensure the ignition, oil gun and coal pulverizer set the security of the system start and stop and operation. Fuel security system is the function of boiler ignition in before and after the tripping of boiler stop blowing on the hearth of Saul, prevent the accumulation of combustible chamber. In the test to endanger equipment, the personal safety of operation condition, start main fuel trip (MFT), quickly cut off fuel, an emergency stop furnace.
Keywords: FSSS, main fuel trip, boiler hearth bums, prevent bums
中图分类号:P624.8文献标识码:A 文章编号:
1、MFT
主燃料跳闸(MFT)是FSSS系统中最重要的安全功能,当出现任何危及锅炉安全运行的危险工况时,MFT动作将快速切断所有进入炉膛的燃料,即切断所有煤和油的输入,实现紧急停炉,汽机跳闸,以保证设备安全,避免重大事故发生。同时,该逻辑中具有首次跳闸原因指示功能,它能对引起主燃料跳闸的最初原因记忆并在CRT上显示出来,为故障原因分析及解决提供了条件。
临界火焰是蒸发量1000t/h及以上锅炉“基于单个燃烧器的火焰监视和灭火保护”FSSS系统的重要监视逻辑之一,是对燃烧器火焰着火区进行“点监视”的火检系统中才存在的特有逻辑条件。出现了临界火焰时,如果不产生MFT则会在炉膛中形成可燃性混合物的积累,进而引起炉膛爆燃事故的发生。“临界火焰”触发MFT的特殊性在于:锅炉尚未灭火,处于事故萌发之前的不稳定临界状态,由这种状态引发MFT,可以预见爆燃事故的发生。……