地下室防渗混凝土施工技术的探讨
2012-04-10余小东
余小东
摘要:随着经济和施工技术的不断发展和土地资源的日渐匮乏,高层甚至超高层建筑越来越多,广东地区由于地下水位高、地理环境复杂且地下水中含有多种有害物质对混凝土乃至钢筋产生腐蚀作用,因此地下室混凝土渗漏开裂的现象比较普遍,并逐渐成为一个老大难问题。因为地下室混凝土的渗漏开裂不仅影响到建筑物的正常使用,还影响结构的耐久性和使用安全。本文结合具体工程讨论高层建筑物地下工程防渗混凝土施工技术。
关键词:地下室;防渗膨胀混凝土;施工技术
Abstract: with the economy and the construction technology development and the land resource of the increasingly scarce, top even tall building more and more, the guangdong area due to high ground water level, geographical environment and complex contains a variety of harmful substances in the groundwater of concrete and reinforced corrode, so the basement of the cracking of concrete leakage phenomenon are quite common, and gradually become a long-standing problem. Because the basement leakage of the concrete cracking not only affect the normal use of the building, but also affect the structure of durability and use the security. This paper discussed the specific engineering high-rise buildings underground impervious engineering concrete construction technology.
Key words: the basement; Seepage control inflation concrete; Construction technology
中图分类号:TU74文献标识码:A 文章编号:
一、工程概况
某建筑工程总面积约98278,6m2,地基为中风化岩,地下为一层13275.84平方米,地上两栋楼均为19层高层建筑物。结构类型:框架剪力墙结构,基础采用冲孔灌注桩。本工程按二级防水构造措施设防,均为外防水,抗渗等级为P8。地下室基础底板、外墙、顶板混凝土强度等级为C35,,地下室剪力墙、柱为C40,地下室底板伐板厚800mm,其中高层部分联合承台厚度2.40m,纯地下室外墙厚350mm,地下室顶板厚为250mm。
二、膨胀带及滑动层的设计
设置膨胀带和滑动层,可以减少后浇带的数量,方便施工。