摘要:FTTX建设模式中,FTTB(光纤到大楼)建设中,经常遇到设备供电过程中,需要协调供电部门或物业管理,同时由于设备本省没有UPS,局部电源故障会导致整个大厦或者大楼不能正常使用的问题,且大量设备运行过程中也面临设备运营成本较高和节能降耗的问题。本文从反向供电角度技术入手提出可行的建议供参考。
关键词:FTTB 反向供电 POE FTTX 节能降耗
Abstract: the construction model of FTTX, FTTB (fiber to the building) construction, often encountered in the process of power supply equipment, need to coordinate the power supply departments or property management, and because the equipment this province no UPS, local power failure will cause the whole building or building can't normal use and large equipment operation in the process also faced equipment operation cost and higher energy saving of the problem. This paper, from the Angle of reverse power technology practical Suggestions for reference.
Key words: FTTB reverse power supply POE FTTX saving energy and reducing consumption
中图分类号:U223.5 文献标识码:A文章编号:
最近几年FTTX建设模式在各大通信运营商和广电企业中被普遍认可,目前进入大规模商用阶段。在此建设过程中,FTTB(光纤到大楼)建设模式由于其布置灵活,通过光接口的有源设备为用户提供语音、宽带服务,但由于光纤不能传送设备所需电能,需要就近取电,需要和供电或物业管理部门签订用电协议;另外FTTB设备处于无人值守状态,必须24小时处于运行状态,虽然需要提供24小时不间断上网服务,但大部分用户使用时间在夜间,白天较空闲,一定程度上是一种浪费。不仅如此,在许多企业用户通过局域网交换机建设的FTTB+LAN模式也存在设备24小时运行,但真正使用的效率仅有20%左右,80%左右的端口和时间设备都在空转,不仅耗电也会造成设备寿命的缩短。
笔者借鉴POE电源的工作原理,通过引入反向供电技术的应用,解决以上面临的问题。从目前已应用的项目反馈情况看,有较高的推广应用价值。通过用户侧电源提供设备所需电力,实现用户何时使用,设备何时运行,多个用户使用,均摊供电负荷,从而实现节能降耗,延长设备寿命的目的。……