船舶大功率负载起动方式选择及应用
2025-07-28唐文合谈萍刘冰李屹赵彬睿
中图分类号:U662.2文献标志码:A
Selection and Application of Starting Methods for High-Power Loads in Ships
TANG Wenhe, TAN Ping, LIU Bing, LI Yi, ZHAO Binrui (Guangzhou Shipyard InternationalCompanyLimited,Guangzhou,China)
Abstract: The stability of ship power grids is a critical guarantee for safe ship operation. This paper systematicall analyzes the technical characteristics of starting methods for high-power loads,including direct starting,star-deltastarting,autotransformer starting,softstarting,andvariable frequency starting.Acomprehensive selectio method is proposed based on transient voltage drop verification,starting torque matching,and step-loading capability.Through a case studyofa specific ship type,the feasibilityoftheselected starting methods is validated, and a step-loading strategy for high-power loads across the entire ship is formulated.This research provides theoretical and practical references for ship power system design.
Key words: ship power grid; transient voltage drop; starting methods; step-loading
1 引言
船舶电站系统是船舶的“心脏”,其稳定性直接关系到全船设备的正常运行与航行安全。随着船舶大型化与自动化水平的提升,大功率负载(如舱底总用泵、主滑油泵、海水冷却泵等)的应用日益广泛,此类负载的起动电流可达额定电流的6\~8倍,若未合理选择起动方式,将导致发电机端电压骤降、保护装置误动作等连锁故障。因此,如何平衡起动电流抑制、起动转矩需求及经济性,成为船舶电力系统设计的核心挑战之一。本文结合工程实例,探讨船舶大功率负载起动方式的选择策略,以期为行业提供参考。
2 起动方式的重要性
船舶大功率负载主要是电动机,大功率电动机的起动会带来较大的起动电流,从而对船舶电网带来较大冲击,可能会引起船舶电网的瞬态电压降超标,过大的瞬态电压降会导致设备无法正常工作,引起继电保护装置的误动作,甚至可能会引起全船失电,给船舶的正常运营带来安全隐患。因此,在进行全船电力系统设计时,需根据负载特性、电网容量及规范要求,对各类大功率负载选择合适的起动方式,确保瞬态电压降控制在安全范围内,避免因过大起动电流引起船舶运营的安全。
3 起动方式的分类
3.1直接起动
直接起动方式是最常用的起动方式,其起动方式简单,起动器成本较低。直接起动方式可提供较大的起动转矩,但同时起动电流也最大,一般是额定电流的6\~7倍,对电网冲击影响显著。……