Abstract: This study established a gas chromatography method for the detection of saccharin in food.The experimental derivatization reaction and chromatographic conditions were studied,and the linear range,accuracy, and precision of the method were investigated.The results showed that there was a good linear relationship between saccharin and 10.0~200.0μg⋅mL-1 0 (r2=0.9995 ), the detection limit of the method was 0.01mg⋅kg-1 , and the relative standard deviation (RSD) of precision was ⩽3.76% .At three spiked levels, the average recovery rate of saccharin in three types of food matrices was 89.7% to 101.3% .The test results of 42 commercially available samples showed that the highest exceedance rate of saccharin was in the candied fruit category, at 28.6% ,while beverages and pastries did notexceed thestandard.Thismethodhas highsensitivityand goodreproducibility,andissuitable forrapiddetection of saccharin in food,providing reliable technical support for market supervision.
Keywords: sweetener detection; gas chromatography; food
甜蜜素作为一种人工合成甜味剂,其甜度为蔗糖的 30~50 倍,广泛用于蜜饯、饮料等食品中。然而,其代谢产物环己胺具有潜在毒性,因此联合食品添加剂专家委员会规定每日允许摄入量为11mg⋅kg-1 bw体重。现行国家标准检测方法存在前处理复杂(耗时 gt;4h )、灵敏度不足(检出限0.02mg.kg-1 )等瓶颈,限制了其在实际应用中的效率与准确性。本研究通过气相色谱衍生化反应,将强极性目标物转化为挥发性衍生物,显著提升了检测选择性与灵敏度[1-2]。
气相色谱法(GasChromatography,GC)检测甜蜜素具有显著优势,通过亚硝化衍生反应将强极性甜蜜素转化为挥发性 N- 亚硝基环己基氨基磺酸酯,可以规避食品基质干扰。相比液相色谱法,该方法前处理步骤减少 40% (由7步优化至4步),方法检出限降低至 0.01mg.kg-1 (较国标提升 50% )。优化后的 HP-5 色谱柱实现 18.3min 快速分离,峰形对称因子在 0.95~1.05 。质控数据显示,在高糖(如蜜饯)与高脂(如糕点)基质中,信号抑制率分别低于 3.2% 和 7.8% ,满足《食品安全国家标准食品中环己基氨基磺酸钠的测定》(GB5009.97—2016)要求。
本研究建立一种能高效检测食品中甜蜜素的气相色谱技术,通过优化衍生化反应体系与色谱分离条件,重点解决复杂食品基质干扰、痕量组分检测稳定性等关键技术难点。该技术可为食品中甜蜜素的风险监测及标准执行提供可靠的技术支持,对保障消费者健康具有重要的现实意义。
1材料与方法
1.1材料与试剂
实验材料选取了市售饮料、蜜饯、糕点等3大类共42份食品样品,采样后经均质化处理并分装,于 -18% 条件下保存。……