Preliminary investigation of building damage in Hatay under February 6, 2023 Turkey earthquakes
2023-11-13WangTaoChenJieZhouYujiangWangXiaoqingLinXuchuanWangXiaotingandShangQingxue
Wang Tao, Chen Jie, Zhou Yujiang, Wang Xiaoqing, Lin Xuchuan, Wang Xiaoting and Shang Qingxue
1. Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150080, China
2. Key Laboratory of Earthquake Disaster Mitigation, Ministry of Emergency Management, Harbin 150080, China
3. Institute of Earthquake Forecasting, China Earthquake Administration, Beijing 100036, China
4. Department of Civil Engineering, Tsinghua University, Beijing 100084, China
Abstract: On February 6, 2023, an Mw7.8 earthquake hit the south of Kahramanmaras prefecture, Turkey, followed by another Mw7.5 earthquake after nine hours in the middle region of the Kahramanmaras prefecture. More than 84,000 buildings collapsed or were severely damaged, and more than 50,000 lives were lost in Turkey and Syria. Some of the authors, as members of Chinese rescue team, entered Antakya, Hatay prefecture, and investigated the damaged buildings. This paper first summarizes the damage patterns of buildings and provides three reasons for the massive number of collapsed buildings; i.e.,the lack of seismic measures for better ductility, site effects such as liquefaction and surface rupture, and pronounced lowfrequency components of the ground motions. Next, the seismic responses of two typical buildings are calculated based on the geometric data estimated by visual inspection. The results imply that the resonance of the whole structure and the poorer ductility of key members resulted in the collapse of buildings. Finally, some conclusions are drawn. Note that although a large number of buildings were seriously damaged to collapse, the majority of buildings in the areas of extreme shaking were lightly or moderately damaged, which implies that well designed and constructed buildings were able to survive and protect human lives even in over-design earthquakes.
Keywords: Turkey earthquakes; collapsed building; seismic measures; low frequency components; building relics
1 Introduction
At 4:17 AM local time, Feburary 6, 2023, anMw7.8 earthquake hit at the south part of Kahramanmaras,Turkey. After nine hours, at 1:24 PM, a secondMw7.5 earthquake happened at the middle of Kahramanmaras,about 100 km north to the epicenter of the first earthquake.Turkey is located on the Anatolian microplate which is pushed to the Eurasian plate by the Arabian plate with the moving speed about 1–2 cm/a to the north (Richard and Marco, 2020) . Since the Eurasian plate is heavy,the Anatolian microplate is extruded to the west, and forms the complex left-lateral east Anatolian fault and the right-lateral north Anatolian fault (Duman and Emre,2013). The east Anatolian fault forms a left-lateral strikeslip fault zone where the two eartqhuakes happened, as shown in Fig. 1. TheMw7.8 earthquake occurred on the Pazarcik segment of the southern (main) strand of the east Anatolian fault, while theMw7.5 happened on the Nurhak-Cardak segments of the northern strand of the east Anatolian fault (Dumanet al., 2023).
Since the beginning of the last century, many earthquakes have occurred along the east Anatolian fault with magnitudes larger thanM6.0, such as the 1905M6.8 Sincik earthquake, the 1975M6.7 Lice earthquake,and the 2020M6.7 Doganyol earthquake, which indicate that seismic activity is frequent. The two earthquakes on Febuary 6, 2023, are probably the largest earthquakes to ever occur on this fault (Başarır Baştürket al., 2017) .

Fig. 1 Fault distribution around Anatolian microplate

Fig. 2 Distribution of history earthquakes in east Anatolian falut

Fig. 3 Location of mainshock and aftershocks
Since the first mainshock, there have been 390 aftershocks with magnitudes larger thanM3.5; among them, 40 were larger thanM5.0, until March 15 (AFADTADAS, 2011). The largest aftershock with a magnitude ofMw6.7 occurred 17 minutes after the first mainshock(AFAD-TADAS, 2011). After two weeks, anotherMw6.4 aftershock hit the south region of Hatay province. These strong aftershocks were distributed along the north strand and the south strand of east Anatolian fault. The sequence partially reflects the stress redistribution,accumulation and fracture processes in the crust (Cetinet al., 2023).
The isoseismal map of instrumental intensities of the two major earthqukes are shown in Figs. 4(a) and 4(b),respectively (USGS, 2022). The largest intensity of theMw7.8 earthquake isX, distributed along the Amonos segement of the south strand of the east Anatolian fault,from the city Hassa to Antakya. The largest intensity of theMw7.5 earthquake was VIII.
Many observation stations of strong ground motion are placed along the causitive faults; the locations are shown in Fig. 4.
These earthquakes primarily affected 11 provinces,as listed in Table 1. About 16% of the population was affected and the GDP in these area was about 10% of the whole country. Note that there has been a 10-year economic boom since 2000 in Turkey; meanwhile, many buildings have been constructed during this time period and were the majority in most of the affected provinces.(Cetinet al., 2023)
2 Characteristics of strong ground motions
According to the finite fault model provided by USGS, the rupture of theMw7.8 earthquake initiated from a small fault segment to the northeast and connected to the main strand of east Anatolian fault, then spread to the northeast and the southwest along the main strand. The total ruptured length is about 265 km, specifically, 125 km to the northeast and 140 km to the southwest. The rupturelasted for about 120 s. TheMw7.5 earthquake occurred on the north strand of east Anatolian fault. The length of rupture is about 100 km and the rupture lasted for about 60 s (USGS, 2022).

Table 1 Statistics of earthquake-affected provinces
2.1 Location of observation stations and strong ground motion data
The location of observation stations of strong motion are shown in Fig. 4. Table 2 lists related information about the type of station and recorded PGA, PGV and PGD.
Several stations along the north and the south strands of east Anatolian fault were selected to examine the characteristics of ground motions, as shown in Fig. 5.Seven stations, 4611, 4615, 3143, 3139, 3123, 3135 and 213, recorded strong ground motion of theMw7.8 earthquake. These stations were placed along the main fault, and station 4615 is closest to the epicenter. The epicenter distance and the site type (Europe standard) of each selected station are shown in Table 2. The records from three stations, 4612, 4406 and 4611, were selected for theMw7.5 earthquake. Among the three stations,station 4611 is closest to the epicenter, but perpendicular to the rupture direction. The largest records were obtained at station 4612, which is 67 km from the epicenter but along the rupture direction (AFAD-TADAS, 2011).

Fig. 4 Isoseismal map of Turkey earthquake and location of observation stations
2.2 Typical strong ground motions and response spectrum of Mw7.8 earthquake
The time histories of the recorded ground motions are shown in Fig. 6, together with the acceleration response spectra in three directions. The peak ground accelerations (PGA) recorded at station 4615, the closest one to the epicenter, were 0.56 g, 0.6 g and 0.67 g in the east-west (EW), north-south (NS), and vertical(UD) directions, respectively. With the propagation of the earthquake wave, the PGA becomes smaller in the north-east direction, as recorded by stations 4611 and 213, while becomes larger in the south-west direction.At station 3135, a PGA of 1.34 g was recorded in the EW direction, and at station 3123, a PGA of 0.86 g was recorded in the UD direction. The high peak acceleration comes from a sharp pulse, which might be caused by an occasional factor.
The acceleration response spectrum indicates the frequency contents of a ground motion. The long period contents from 1 s to 2 s are pronounced in the horizontal directions for the records from stations 3143, 3139,3123, and 213, and the low period contents of less than 1 s dominate in the horizontal direction for the rest of the records. The reason might be pluralistic. The fault mechanism, propagation route, topography, site type,and so on, are among the potential reasons for the different dominated periods in various station records.
2.3 Typical strong ground motions and response spectrum of Mw7.5 earthquake
The records from stations 4612, 4406 and 4611 are examined for theMw7.5 earthquake. The closest station is 4611 with the epicenter distance as 38 km. However,it is not located on the ruptured fault, and the PGA is 0.2 g, much smaller than the one recorded at station 4612 located on the fault, 0.64 g. The records obtained from station 4612 contain useful long period contents from 1 s to 2 s in the horizontal directions.
3 Investigation of building damage in Antakya
Based on the preliminary reconnaissance report(Cetinet al., 2023), the statistical data of buildings with various damage states are listed in Table 3. About 11% of the buildings in Malatya have been examined,and of these, 32.5% were found to be heavily damaged or collapsed. In Hatay and Kahramanmaras provinces,14% and 19% of the buildings were examined. Heavily damaged or collapsed buildings comprised about 23.6% and 21.6%, respectively. In Gaziantep, heavily damaged or collapsed buildings comprised 9.5% of the examined buildings. However, the absolute number is close to 13,000. The first and fifth authors entered Hatay province on February 8, two days after the earthquake.The damage to buildings was investigated, and the damage patterns are discussed herein.
3.1 Remote sensing of buildings in Antakya
Antakya has a population of 270,000 people. Most buildings are RC frame structures with a small numberof walls. Most buildings are 6 to 10 stories tall. Figure 8 shows the remote sensing image of Antakya, from which the collapsed buildings can be identified. There is a river flowing through the city from north to south.More buildings were damaged or collapsed on the west bank of the river than on the east. One of the reasons is speculated that the west bank is much closer to the fault,or the west bank has a thicker sedimentary layer. Three blocks along the river were investigated.

Table 2 Ground motion data of each station

Table 3 Statistics of seismically damaged buildings

Fig. 6 Typical time histories of strong ground motions and response spectrum of Mw7.8 earthquake
3.2 Damage states of buildings

Fig. 7 Typical time histories of strong ground motions and response spectrum of Mw7.5 earthquake
Basically, three collapsed modes can be classified as types, i.e., overturned collapse, laminated collapse,and story collapse, as shown in Figs. 9(a), 9(b), and 9(c), respectively. If the columns on the same side in the bottom story sustained larger axial force than the other side, due to the overturning moment, they would fail earlier. Then the large lateral inertial forces in the upper stories would further overturn the building. In this case,the slabs are generally aligned in parallel and large spaces for people to survive existed, as shown in Fig. 9(a).Another case is that the columns in the first story lost their bearing capacity at the same time because of the large axial force ratio under the gravity. The margin to resist earthquake action is very limited. If the upper stories were also built with low strength material, they would collapse subsequently to the first story and the slabs finally piled one above another, as shown in Fig. 9(b).However, if the upper stories were strong, they would survive during the earthquake, and finally became a“shortened” building, as shown in Fig. 9(c). A building under construction was observed on site. The bottom stories collapsed and several columns in the fourth story still supported the upper stories, as shown in Figs. 9(d)and 9(e). The columns in the other side, however, all failed, and some penetrated the slab to the upper stories,as shown in Fig. 9(f). It was observed that rectangular columns with a large length-to-width ratio, about 3–5,were widely used in Turkey. This type of rectangular column is good for the architecture, and also provides large stiffness and strength in the long direction. If the column were designed with sufficient ductility in any direction, this structure system could be suitable for seismic resistance and collapse prevention. However, it was often observed on site that the column in the long direction was damaged prematurely, while the rest was not enough to resist the huge earthquake. This was more often the case in buildings built before 2000.

Fig. 8 Remote sensing map of buildings in Antakya
Many buildings were seriously damaged during the earthquake and on the verge of collapse. Shown in Fig. 10(a) is a ten-story RC frame building. Although it survived the earthquake, the RC beam-to-column joints and beam ends have been damaged completely. It can be observed in Fig. 10(b), the earthquake resulted in concrete spalling off at the beam-to-column joints and the steel rebars are exposed. Similar damage can be observed in Fig. 10(c), where a shear crack penetrated the whole beam-to-column zone. Figure 10(d) exhibits the bending, and the bending-shear mixed cracks on the RC beams. The vertical bearing capacity was provided only by the rebars with tensile suspension effects.Although the residual deformation was hardly identified,the building was on the verge of collapse.
In the downtown area, some buildings were moderately damaged or slightly damaged. One building that was under construction is shown in Fig. 11(a), which is a ten-story building with one story underground. The infilled masonry walls had been constructed, and only a small number of them were destroyed during the earthquake. This building is an RC frame-wall dual structural system. The section length of the wall is about 1–2 m. As shown in Fig. 11(b), the column foot and the beam end were damaged. As shown in Fig. 11(c), the coupling beams, as the first seismic defense line, were seriously damaged. Both bending cracks and shear cracks were observed. Concrete was crushed at the toes of the wall and damage was also observed at the construction joints where steel rebars were buckled, as shown in Figs. 11(d), 11(e) and 11(f). Nevertheless, the components bearing the vertical loads were not seriously damaged. Therefore, the whole building successfully resisted the huge earthquake actions.
Another building close to the downtown of Antakya was a five-story RC frame-wall structure, as shown in Fig. 12(a). It was under construction and the infilled walls had not been installed. There was no damage observed on the primary structural components, such as columns, beams, and walls. The RC stair was damaged at the fourth story due to the geometric irregularity.

Fig. 9 Modes of collapsed buildings for reinforced concrete structure

Fig. 10 Severely damaged buildings of reinforced concrete structure
4 Preliminary analysis of building damage and collapse
4.1 Reasons for building damage and collapse
One of the reasons for building damage and collapse was the insufficient seismic fortification measures,particularly for old buildings. As shown in Fig. 13(a),the constitution of the concrete mixture was not suitable to provide the strength required. The characteristic size,percentage, and strength of coarse aggregate were not well prepared, which leads to the brittleness of concrete.Some old buildings used steel rebars with a smooth surface, as shown in Fig. 13(b). The bond between the concrete and steel was not sufficient and could not make full use of the strength of the rebars. Moreover, the splice of the rebar with a smooth surface could not efficiently transfer the force. The lateral stirrups that provide confinement to the concrete were found to be insufficient as well. As shown in Figs. 13(b) and 13(d), the distance of the stirrups was about 300 mm, almost double the value required by most design codes. Furthermore, the lateral rebars were formed as a single stirrup, which could not provide sufficient confinement. The damage to an RC wall is shown in Fig. 13(e). The concrete failed first, then led to the buckling of the vertical steel rebars. The horizontal rebars were much thinner than the vertical ones, and were unable to bear large shear force. The wall failed in a shear damage pattern. It was also observed that there was no boundary confinement zone at the end of the wall sections, as shown in the red dashed box in Fig. 13(e). The ductility of the wall (or columns with cross sections) was very low. Once it was damaged during an earthquake, the lateral resistance dropped sharply and led to the overall collapse of the building.

Fig. 11 Moderately damaged buildings of reinforced concrete structure

Fig. 12 Lightly damaged buildings of reinforced concrete structure
The USGS predicted liquefaction probability immediately after the firstMw7.8 earthquake. It was supposed that there were large amounts of liquefaction in Antakya. However, the authors did not inspect the liquefaction during the investigation in the blocks 1–3 shown in Fig. 8. Nevertheless, the preliminary reconnaissance report provided useful photos of liquefaction, as shown in Fig. 14. The liquefaction introduced engineering damage was reported in Iskenderun and Golbasi. Some seriously affected buildings had maximum foundation settlement of about 80 cm, resulting in a tilt angle of about 5%–10%. One building in Golbasi, shown in Fig. 14(e), overturned completely because of the foundation failure due to liquefaction. However, the structure remained integral(Cetinet al., 2023).
Another reason for building collapse in Antakya was the over-design ground motions. The ground motions recorded by the stations in Antakya, as shown in Fig. 15(a),were examined by providing the acceleration response spectra. The PGA of most records was larger than the design basis earthquake (DBE) with PGA of 0.5 g, and some were larger than the maximum credible earthquake(MCE) with PGA of 1.0 g, as shown in Fig. 15(b)(Kadirioğluet al., 2018). More importantly, some ground motions contained pronounced long-period components, as given by station 3123, which was close to the first investigation block in Fig. 8. The acceleration response spectra is given in Fig. 15(c). Pronounced peaks can be clearly observed around the period of 1 s,which is similar to the fundamental period of buildings with 10 stories, or 30 m high. Therefore, strong resonant vibration would impose large actions on the building and resulted in massive collapse.
Two surface ruptures were spotted at Hassa and Kirikhan, and the buildings around the ruptures are shown in Figs. 16 and 17, respectively. Both were from north to south. At Hassa, the surface rupture crossed a street,and passed through several buildings. The buildings on the rupture were destroyed, as shown in Figs. 16(a) and 16(b). The RC frame structure collapsed in the first story,while the two masonry buildings collapsed completely.Along the rupture to the north, the land uplift was observed to be about 80 cm, as shown in Fig. 16(c). The surface rupture crossed another two parallel streets. The dislocation of the street was very clear. From Fig. 16(d),the dislocation was about 2 m, and the left-lateral strikeslip fault can be identified. Going along the rupture to the south, there was a building about 10 m away from the rupture, as shown in Fig. 16(e). It survived the earthquake with slight damage. The land uplift was observed in the south direction as well, as shown in Fig. 16(f), which passed through a three-story residential building. The building was seriously damaged, as shown in Fig. 16(g),with the first story deformed in the west direction, and the residual drift was about 40%. If it was not leaning on the neighboring building, the first story would have collapsed.

Fig. 14 Liquefaction resulted building damages (Cetin et al., 2023)
The surface rupture was spotted on a steep slope,where two ruptures developed in parallel and with the distance about 40 m, as shown in Fig. 17(a). It extended to the south direction and passed through a two-story building. However, the building survived, as shown in Fig. 17(b). The reason might be the foundation of the building was well constructed and the rupture was not so big. The rupture further extended to the south along a street and passed by a seven-story building, as shown in Fig. 17(c). The building may have experienced some damage and shear cracks can be observed on the outside walls. Generally, the buildings neighboring the surface rupture at Kirikhan were less damaged than those observed on the buildings close to the rupture at Hassa. Better foundations may significantly reduce the dislocation effect of surface ruptures. It is also interesting that the surface rupture imposed significant actions on the buildings it directly passed through, while the effect sharply reduced as the distance to the rupture increased.Similar phenomenon was also observed in 2008Mw7.9 Wenchuan earthquake, China.
4.2 Typical buildings and collapse modes

Fig. 15 Location of station 3123 and acceleration response spectra compared with DBE and MCE spectra

Fig. 16 Buildings across surface rupture at Hassa
Two typical buildings under construction were selected for further study by nonlinear time history analyses. The buildings, as shown in Fig. 12 and Fig. 9(d),are 5-story and 9-story RC frame structures with a small number of RC walls. The 5-story building demonstrated good seismic performance, as shown in Fig. 12, and did not suffer significant damage, while the 9-story building collapsed during the earthquake, as shown in Fig. 9(e).Because both buildings were under construction, it is possible to identify the dimensions of the structural members and the geometry of the two buildings. Note that the dimensions were estimated from the photos,but not measured. The plan views of the buildings were reproduced from photos, as shown in Figs. 18(a) and 18(b). The 5-story building had four spans in the long direction and two spans in the short direction. The total length was about 19.2 m and the width of building was about 9.3 m. The story height was 3 m. There were several pieces of walls in the middle of the building, which were designed as U-Shaped or L-shaped walls and used as the elevator tube and staircases (TSC-2007, 2007). The 9-story building had four spans in both directions. The span length was about 6 m. The story height was also identified as 3 m. There were several L-shaped walls in the middle of the plan. These walls, however, were placed eccentrically and led to torsional irregularity as defined by Turkish seismic design code TSC-2007(2007). The columns in both buildings have rectangular sections with a length-to-width ratio larger than 2.0,which was typical in local buildings. If the length-towidth ratio was larger than 4.0, then the component was identified as a wall member.
The Turkish seismic design code TSC-2007(2007) specifies the following requirements for the reinforcement of concrete columns: the longitudinal column reinforcement shall not be less than 1% or more than 4% of the gross section area, and the longitudinal reinforcement ratio shall not exceed 6% at lap spliced sections. According to the field survey, the steel rebars in columns were not sufficient so that the lowest values satisfying the seismic design code, 1%, was adopted for all columns and walls.
The calculation Eq. (1) for the reinforcement of concrete beams can be found in the Turkish concrete design code TS-500 (2002):whereρminis the longitudinal reinforcement ratio at the top and bottom of the beam support section,fctdis the design axial tensile strength of the concrete, andfydis the design yield strength of the longitudinal reinforcement.The authors found during the field survey that the concrete grade and the steel rebar grade were not very high and could be similar as Chinese C30 and HPB300,respectively (GB/T 228.1-2010, 2011). The strength was taken as 14.2 MPa and 300 MPa, as suggested by the Chinese concrete design code (GB 50010-2010, 2015).Then, the minimum reinforcement ratio of the beams was calculated to be 0.4%. The reinforcement ratio was finally adopted as 0.8% for the beams in both buildings.

Fig. 17 Buildings near surface rupture at Kirikhan

Fig. 18 Plan views of two typical buildings

Table 4 Cross-section information of FEM

Fig. 19 Constitutive models

Table 5 Periods of two models (Unit: s)
The Turkish seismic design code TSC-2007 (2007)also specifies the total cross section area of each of the vertical and horizontal web reinforcements on both faces of the structural wall shall not be less than 0.0025 of the gross section area of the wall web. Although the wall end zone is required by the code, it was rarely observed during the field reconnaissance. Therefore, the steel rebars are supposed uniformly distributed along the wall length and the reinforcement ratio was taken as 0.3%.
Dimensions and reinforcements of each member used in the finite element model (FEM) are listed in Table 4. Note that the minimum allowable reinforcement ratios were used for most members. OpenSees (Mckennaet al., 2018) was then used to model and analyze the two buildings. The columns, beams, and walls were all modeled by fiber-based nonlinear beam-column elements with distributed nonlinearities. The uniaxial concrete model named concrete04 (Manderet al., 1988)was employed to simulate the concrete stress-strain behavior considering the confinement effect in the core area. The steel reinforcement was simulated using the bilinear Steel01 constitutive model with kinematic hardening. Both models are shown in Figs. 19(a) and 19(b) for the concrete and the steel, respectively. The rigid diaphragm constraint was applied for each floor to simulate the constraint effect of the slabs. Because both buildings were under construction, only the self-weight was considered as the inertial mass.
Modal analyses were conducted for the two structural models first, and the results are summarized in Table 5.The fundamental period of the 5-story structure is 0.585 s,while that of the 9-story structure is 1.158 s.

Fig. 20 Story drift ratio

Fig. 21 Maximum strain of longitudinal rebars of bottom columns
Using the seismic records from station 3123, which is the closest to the two buildings, nonlinear time history analyses were then conducted. The acceleration response spectra of the records are shown in Fig. 15. It is very clear that the dominant periods of the horizontal components of the records are both close to 1 s, which is very close to the natural period of the 9-story building.Much larger responses would be expected for the 9-story building than the 5-story building, as demonstrated by the maximum inter-story drift ratios shown in Fig. 20.The maximum story drift ratio for the 5-story model was found to be 1/56, and for the 9-story model it was found to be 1/25. If examining the strains in the bottom columns, the strains in the columns of the 9-story model extensively exceed 10,000µε, as shown in Fig. 21.Considering the low ductility of the building observed in the field survey, the 9-story building should collapse as was observed in reality.
5 Conclusions
The Turkey earthquake happened on February 6, 2023, and caused a large number of building collapses and significant human casualties. The authors investigated the damage to buildings in Antakya and analyzed the reasons for their collapse. The conclusions are summarized as follows.
(1) The reasons for building collapse include insufficient seismic fortification measures, engineering site effects, and over-design ground motions. Older buildings, built before 2000, were generally not well seismically designed and constructed. The lack of seismic fortification measures led to poorer ductility and thus caused overall building collapse. The site damage effects included liquefaction and surface rupture, once very close to the building, often caused the foundation failure, and further resulted in the building collapse or severe damage. The over-design ground motion,specifically referred to as the low frequency components full of energy, caused buildings with about 10 stories to resonate during the earthquake and exceeded the capacity of the building.
(2) Although a large number of buildings were seriously damaged to collapse, lightly or moderately damaged buildings were in the majority even in the area of extreme shaking, which implies that well designed and constructed buildings were able to survive and protect human lives even in over-design earthquakes.The structural system using wall-type columns are able to provide large lateral stiffness, however, detailed seismic measures are needed to enhance the ductility.Otherwise, the pre-mature failure of these members leads to cascading failure of other members and finally results in complete collapse of the buildings.
(3) The collapsed buildings formed various types of ruin structures. It has been classified into three types based on the geometric characteristics, i.e., overturned collapse, laminated collapse, and story collapse. In reality, different types may combine to form more complex patterns. This needs further investigation and analysis to determine the structural stability of ruins before starting the rescue activity. However, more effort is needed for the systematic study of this issue in the future, which can help make better decisions on the rescue scheme.
(4) This study only focuses on the buildings primarily damaged by the firstMw7.8 earthquake, because the working area of the authors is located in Antakya, more than 140 km south of the first epicenter and more than 240 km south of the second. The capability of buildings to resist multiple shocks within a short period of time needs further investigation.
Acknowledgment
This study was funded by the National Natural Science Foundation of China for Distinguished Young Scholars under Grant No. 52125806 and Heilongjiang Touyan Innovation Team Program under Grant No. 3016.Any opinions, findings, conclusions, or recommendations expressed in this paper are those of the authors and do not necessarily reflect the views of the sponsors.
杂志排行
Earthquake Engineering and Engineering Vibration的其它文章
- Dynamic characterization of tailing dam using fully coupled dynamic analysis with different boundary conditions – a case study
- Study regarding typical liquefaction damage during the 2021 Maduo Ms7.4 earthquake in China
- Performance of RC buildings after KahramanmaraŞ Earthquakes:lessons toward performance based design
- Application of computational fluid dynamics in design of viscous dampers - CFD modeling and full-scale dynamic testing
- Generalized response displacement methods for seismic analysis of underground structures with complex cross section
- A comprehensive approach to a variability analysis between earthquake activity and hydro-environmental factors on the Korean Peninsula