石蜡光安定性测定仪校准方法研究及其测量不确定度评定
2023-08-13姜天淇王浩刘忆萱
姜天淇 王浩 刘忆萱
【摘要】本文参考SH/T 0404—2008《石蜡光安定性测定法》和GB/T 34097—2017《石油产品光安定性测定法》,对石蜡光安定性测定仪紫外辐照度和温度参数的校准方法进行了详细的介绍,采用直接测量法对其测量值进行不确定度评定,并进行分析。
【关键词】石蜡光安定性测定仪;校准;不确定度
【DOI编码】10.3969/j.issn.1674-4977.2023.04.013
Study on the Calibration Method of Paraffin Light Stability Tester and Its Measurement Uncertainty Evaluation
JIANG Tianqi, WANG Hao, LIU Yixuan
(Liaoning Institute of Measurement, Shenyang 110004, China)
Abstract: With reference to SH/T 0404—2008 Test method for light stability of paraffin wax and GB/T 34097—2017 Test method for light stability of petroleum products. This paper introduces in detail the calibration methods of ultraviolet irradiance and temperature parameters of the paraffin light stability tester, evaluates the uncertainty of the measured values by direct measurement, and analyzes them.
Key words: paraffin light stability tester; calibration; uncertainty
石蠟光安定性测定仪由带有数字显示的温度照度控制单元、紫外光照射加热单元、试样恒温照射室组成。其能将温度和紫外辐照度准确控制在行业所使用的石蜡光安定性测定方法的要求范围内。石蜡光安定性测定仪的工作原理是将试样置于石蜡光安定性测定仪恒温照射室中,在一定温度和紫外光强度下照射一定时间,用仪器测量光照后试样的颜色,从而获得光安定性结果。石蜡光安定性测定仪广泛应用于电子、汽车、航空、手机通信、塑胶、机械等行业。如果石蜡光安定性测定仪没有定期做好校准工作,在使用过程中如果应用了出现故障的仪器,会影响检验结果的准确性。因此本文对石蜡光安定性测定仪的校准方法进行研究,并给出测量结果不确定度的评定和计算方法,为石蜡的光稳定性提供相应的技术保证。
1校准方法的研究
1.1校准的条件
参照GB/T 34097—2017《石油产品光安定性测定法》中的内容。环境条件:室温,相对湿度≤85%。
1.2校准用设备
紫外辐照计:UV-365探头,波长范围320~390 nm,经检定合格。工业铂热电阻:测量范围为(-80~300)℃,分辨力为0.001℃。
1.3计量特性
紫外辐照度:(12.0±0.3)MW/cm2。恒温室温度:(90±1)℃。
1.4校准项目……p>