液化烃(球罐)根部防火阀国产化解决方案

2021-11-28高丽华

今日自动化 2021年8期

高丽华

[摘    要]中石化石家庄炼化分公司新区建设期间,首次遇到國家对液化烃(球罐)根部阀做防火要求,当时设计为进口阀门,费用高,采购周期长,不满足采购需求,为降低采购费用,缩短采购周期,达到液化烃(球罐)根部防火阀设计要求,依据设计技术参数,针对大口径阀门采用国产一体式电液执行机构及阀门,经过自动复位设计,使执行机构具有故障安全性能,并且执行机构采用进口防火罩保护,阀门经过整体防火设计达到了安全完整性等级要求。当火灾发生时,阀门可以自动快速切断介质,保证罐区安全。

[关键词]罐根阀;球阀;防火罩;电液执行机构

[中图分类号]TE65 [文献标志码]A [文章编号]2095–6487(2021)08–0–02

[Abstract]During the construction of the new area of our company, we encountered the national fire protection requirements for the root valve of liquefied hydrocarbon (spherical tank) for the first time. At that time, it was designed as an imported valve. The cost was high and the procurement cycle was long. It did not meet the procurement requirements. In order to reduce procurement costs and shorten procurement Cycle, meet the design requirements of the fire damper at the root of liquefied hydrocarbon (spherical tank). Based on the design technical parameters, this article adopts domestic integrated electro-hydraulic actuators and valves for large-diameter valves. After automatic reset design, the actuators have fail-safe performance, and The actuator adopts imported fire protection cover, and the valve meets the requirements of safety integrity level through the overall fire protection design. When a fire occurs, the valve can automatically and quickly cut off the medium to ensure the safety of the tank area.

[Keywords]tank root valve;ball valve;fire shield;electro-hydraulic actuator

球罐作为一种特殊的压力容器,被广泛用于存储液化石油气、液化天然气、液态丙烯、液态丁烯、液氧、液氮等介质。由于球罐储存的介质大多易燃、易爆、有毒。因此,储罐区一直是石油化工企业防火防爆的重点。

本设计方案以电液联动防火紧急切断阀为主题,以进口防火罩为辅题,设计开发适应易燃、易爆液体与气体罐区有防火要求的球罐紧急切断,提高防火措施,达到安全完整性等级(SIL)要求,保证罐区安全。

1 设计方案

1.1 方案依据

随着《中国石油化工集团公司液化烃球罐区安全技术管理暂行规定》的出台,对球罐根阀设计要求做了规定,要求其密封结构应采用耐火结构并符合ANSI/API STD 6FA或607标准;对快速切断时间也做了相关规定,要求DN50≤5 s,DN65~350≤10 s[1];执行元件包括电磁阀、切断阀均应满足安全完整性等级SIL3要求。……