单向爪游标卡尺示值误差测量结果不确定度 分析与评定

2021-07-09关越

品牌与标准化 2021年2期

【摘要】 本文介绍了单向爪游标卡尺的使用注意事项以及保养维护方法,并采用五等量块对单向爪游标卡尺的示值误差的测量结果进行了不确定度的分析与评定;该文章考虑了可能发生的情况,给出了各项不确定度分量和具体的计算公式和方法、完整的评定过程和与不确定度相关的数据,为开展单向爪游标卡尺测量工作提供参考和帮助。

【关键词】 单向爪游标卡尺;测量结果;不确定评定

【DOI编码】 10.3969/j.issn.1674-4977.2021.02.029

Uncertainty Analysis and Evaluation of Indication Error Measurement Results of One-way Claw Scale

GUAN Yue

(Liaoning Institute of Measurement,Shenyang 110004,China)

Abstract: This paper introduces the precautions and maintenance methods of one-way claw vernier caliper,and analyzes and evaluates the uncertainty of the measurement results of the indication error of one-way claw vernier caliper by using five equal measuring blocks. Considering the possible situations,this paper gives each uncertainty component and specific calculation formula and method,complete evaluation process and uncertainty. It can provide reference and help for the measurement of one-way claw vernier caliper.

Key words: one-way claw vernier caliper;measurement result;uncertainty evaluation

為避免损坏量爪,单向爪游标卡尺尽量不用来测量表面粗糙的物体;测量开始前先要松开单向爪游标卡尺的紧固螺钉,随后轻轻移动单向爪游标卡尺的游标,使测量爪的测量面与待测物接触,夹紧后的被测物不能在单向爪游标卡尺内来回挪动;读数时视线应与尺面保持垂直状态,读数时,紧固螺钉将单向爪游标卡尺的游标固定在单向爪游标卡尺的尺身上,为了避免滑动;使用后用干净的棉布擦净单向爪游标卡尺并均匀涂上防锈油,放入盒内固定位置,然后存放在干燥、无酸、无振动、无强磁的地方。

常用单向爪游标卡尺主尺规格为(0~300) mm、(0~500) mm、(0~600) mm,分度值为0.02 mm,本文仅对(0~500) mm规格的单向爪游标卡尺在300 mm测量点进行测量时,示值误差测量结果进行不确定度的分析与评定。

1 测量方法

1.1 测量设备

五等量块,标称值为300 mm;工作用校验平板。

1.2 环境条件

环境温度:(20±5) ℃,相对湿度不大于80%。

1.3 测量方法

示值误差300 mm的测量应在螺钉紧固和松开两种状态下进行,无论尺框紧固与否,单向爪游标卡尺的测量面与300 mm量块表面接触应能正常滑动。……