单球法校准标准环规的不确定度评定

2021-07-09马超

品牌与标准化 2021年2期

【摘要】 本文主要介绍了用测长机单球法校准标准环规的方法以及测量不确定度的评定,分析了测量结果不确定度的影响因素。为保障环规量值准确可靠提供一种技术手段,对安全生产和高质量制造具有一定指导意义。

【关键词】 不确定度;测长机;单球法;标准环规

【DOI编码】 10.3969/j.issn.1674-4977.2021.02.018

The Evaluation of Uncertainty in Calibration of Standard Ring Gauge by Single Ball Method

MA Chao

(Liaoning Institute of Measurement,Shenyang 110004,China)

Abstract: This paper mainly introduces the method of calibrating standard ring gauge by the measuring length machine of single ball method and the evaluation of measurement uncertainty,It analysis the factors influencing the uncertainty of the measurement results. It provides a technical means to ensure the accuracy and reliability of the ring gauge value,which has certain guiding significance for safe production and high quality manufacturing.

Key words: uncertainty;length measuring machine;single ball method;standard ring gauge

1 概述

标准环规是用来检验和控制被测件极限尺寸的定值量规,具有使用方便,效率高的特点。在实际工作中对标准环规的校准,双钩测量法由于双钩测头的尺寸限制,无论是基于Mahr公司Plm600型号测长机、Trimos公司LABC-NAN0 1100型号测长机或是中图公司SJ5100-lab3000型号测长机等,都无法满足小尺寸环规的校准工作。在环规直径小于14 mm时,双钩测头位置已经接近临界状态,随时可能由于移动操作造成测头碰触从而影响了测量数据的准确性,当环规尺寸更小时双钩法已经无法检测。此时就可以选择单球法测量,故本文主要介绍了用单球法测量直径小于14 mm的标准环规的测量方法和测量不确定度评定。

2 测量原理

2.1 测量依据

JJG 894-1995《标准环规》。

2.2 计量标准

CHOTEST SJ5100-lab3000型号测长机,2等标准环规。

2.3 测量对象

直径为d=9.9996 mm的标准环规。

2.4 环境条件

环境温度:(20±1) ℃,温度变化不大于0.2 ℃/h;相对湿度不大于65%。

2.5 测量方法

1)在测量软件上选择单球法测量标准环规的选项,将被测环规固定到测量台面上并且调好水平位置;

2)选择已经校准好的红宝石测球,点击“测量”按钮,将红宝石测头接触到环规左侧内表面中心位置,锁紧头座,调节工作台前后位置以确定……