重复性及分辨力引入的不确定度分析
2021-06-07李银龙韩帅杨昱刘长海
李银龙 韩帅 杨昱 刘长海



摘 要:运用贝塞尔公式进行A类不确定度评定时,通常包含了重复性和分辨力引入的不确定度分量。文章以FLUKE 5700為标准,将Agilent 34401作为被校准仪表,对其进行不确定度评定,并讲述了重复性引入的不确定度与分辨力引入的不确定度之间的关系。以此为基础,进一步讨论了重复性引入不确定度的读数方法,以及多功能、多量程数字式仪表如何确定分辨力引入的不确定度。
关键词:重复性;分辨力;数字式仪表;A类不确定度
中图分类号:TH701 文献标识码:A文章编号:2096-4706(2021)24-0169-04
Abstract: When the Bessel formula is used to evaluate the type A uncertainty, the uncertainty components introduced by the repeatability and resolution are usually included. This paper takes FLUKE 5700 as the standard, and uses the Agilent 34401 as the calibrated instrument which is evaluated its uncertainty, and describes the relationship between the uncertainty introduced by repeatability and the uncertainty introduced by resolution. Based on this, the numerical reading method of the uncertainty introduced by repeatability and how the multi-function or multi-range digital meters determine the uncertainty introduced by resolution are further discussed.
Keywords: repeatability; resolution; digital instrument; type A uncertainty
0 引 言
进行设备测量时,经常会使用多次测量求平均值的方法来获取设备的“真值”,然而测量设备受方法、仪器、人员、环境等多种因素的影响,会出现食指误差,所以要定期对测量设备不确定去进行评定,以确保测量经常处于良好状态。
在进行不确定度评定时,经常运用A类不确定度或B类不确定的评定。通常情况下,A类不确定度包含了仪器本身分辨力对测量结果造成的影响,因此当我们进行不确定度评定时,不能重复计算,防止评定结果过大。
1 测量结果不确定度来源
对仪器性能指标测量方法进行深入的研究,建立测量模型。分析测量过程,确定不确定度的影响因素,进而转换为不确定度分量。
测量结果的不确定度一般应包含五个部分:(1)测量标准设备本身的不确定度;(2)被检件带来的不确定度;(3)上级测量标准引入的不确定度(测量标准设备溯源引入的不确定度);(4)各种环境因素引入的不确定度,包括温度、湿度等因素;(5)标准设备与被测件的连接系统带来的不确定度,包括失配误差、转接头测量误差带来的不确定度等。……