静钻根植桩抗压抗拔承载性能试验研究
2021-02-21黄晟周佳锦龚晓南俞建霖舒佳明王孟波
黄晟 周佳锦 龚晓南 俞建霖 舒佳明 王孟波



摘 要:通过一组静钻根植桩的现场抗压抗拔静载试验,研究了抗压和抗拔状态下静钻根植桩的承载性能. 对两根试桩的荷载位移曲线进行了比较分析,并采用有效应力法对试桩的极限侧摩阻力进行计算. 试验结果表明:受桩周土体应力状态和桩身泊松效应影响,静钻根植抗拔桩的极限侧摩阻力小于抗压桩的极限侧摩阻力;抗拔桩侧摩阻力完全发挥时的桩顶位置值大于抗压桩侧摩阻力完全发挥时的桩顶位置值;采用有效应力法计算土层的极限侧摩阻力时,需要考虑土层的极限深度(或极限竖向有效应力),当土层深度超过极限值时,采用有效应力法计算土层的极限侧摩阻力需采用极限深度时对应的竖向有效应力值.
关键词:静钻根植桩;竹节桩;承载力;抗拔系数
中图分类号:TU47 文献标志码:A
文章编号:1674—2974(2021)01—0030—07
Abstract:The bearing capacity of pre-bored grouted planted (PGP) pile under compression and tension is investigated based on a group of field compression and tension tests. The load-displacement curves of two test piles are compared and analyzed, and the effective stress method is adopted to estimate the shaft capacity of the test piles. The test results show that: the ultimate shaft resistance of PGP pile under tension is smaller than the ultimate shaft resistance of PGP pile under compression, due to the different stress conditions of the soil around the pile and the Poisson's ratio of pile shaft; the pile head displacement needed to fully mobilize the shaft resistance of test pile under tension is larger than the displacement needed to fully mobilize the shaft resistance of test pile under compression; a ultimate depth (or ultimate vertical effective stress) exists when the effective stress method is adopted to calculate the ultimate skin friction of the soil layers, and the value of the vertical effective stress corresponding to the ultimate depth should be adopted in the calculation of ultimate skin friction in effective stress method.
Key words:pre-bored grouted planted pile;nodular pile;bearing capacity;uplift coefficient
靜钻根植桩是一种由预应力高强混凝土桩和桩周水泥土组合而成的一种新型组合桩基础,目前在我国东南沿海地区已经有了一些成功应用,并在软土地基中表现出了较好的承载性能[1]. 笔者课题组通过静钻根植桩的现场静载试验研究发现静钻根植桩在软土地基中的承载性能优于传统钻孔灌注桩,且静钻根植桩施工过程中的泥浆排放量相比钻孔灌注桩也有了大幅度减小[2-3].由于静钻根植桩桩身结构的复杂性,其荷载传递机理与传统的预应力管桩和钻孔灌注……