一起发电机模拟电气事故停机导叶未全关事件分析
2021-02-21解志罗天贵吴廷野何学艳徐晓伟
解志 罗天贵 吴廷野 何学艳 徐晓伟

摘要:机组模拟电气事故停机是检验机组停机流程、调速器、励磁装置、继电保护及管路等的设计、制造和安装质量最重要的试验项目之一,是水轮发电机投入商业运行前的一项重要试验。本文深入剖析一起发电机模拟电气事故停机导叶未全关事件分析,找到事件的原因,并提出后期避免类似事件相应的处理办法,供后期同类型水电组甩负荷时参考。
关键词:电气事故;导叶;事件分析
Abstract:Unit simulated electrical accident shutdown is one of the most important test items to test the design, manufacturing and installation quality of unit shutdown process, governor, excitation device, relay protection and pipeline. It is also an important test before hydro generator is put into commercial operation. This paper deeply analyzes an event that the guide vane is not fully closed during the simulated electrical accident shutdown of the generator, finds out the cause of the event, and puts forward the corresponding treatment methods to avoid similar events in the later stage, which can be used as a reference for the load rejection of the same type of hydropower unit in the later stage.
Keywords:Electrical accident;Guide vane;Event analysis
引言
某巨型水電站安装12台850MW水轮发电机机组,电站装机容量10200MW,是国家“西电东送”的骨干电源点,左右岸各安装6台水轮发电机组。右岸机组额定转速为93.75r/min,机组上游设置快速闸门,快速闭门时间3.5min,分别在中控室模拟返回屏、快速闸门现地控制柜和水轮机后备保护柜设置快速闸门闭门按钮。机组设置三级过速保护,电气一级过速定值为转速大于115%额定转速,电气二级过速定值为转速大于148%额定转速,机械过速定值为转速大于155%额定转速,其中电气一级过速动作&2个以上的剪断销剪断则延时2S落快速闸门,电气二级过速和机械过速动作延时1S落快速闸门。机组设置有电气事故保护(MARK0)、一类机械事故(MARK1)和二类机械事故(MARK2)保护。其中发电机及主变电气主保护动作后启动紧急停机流程,一类机械事故和二类机械事故动作后启动快速停机流程。紧急停机流程:解列——停调速器——投机械制动——投锁定、停水导外循环系统——投蠕动探测——停高压油系统——液压系统,辅助设备等——机组技术供水系统运行。……