常压塔顶腐蚀堵塞原理及应对措施
2020-12-17姜陆
姜陆



摘 要:结合多年实际生产情况,对炼厂常减压装置内常压塔顶及冷却系统的设备、管道出现的减薄、穿孔、垢下腐蚀、堵塞等现象的具体原因进行了理论分析,找出腐蚀、堵塞等问题的深层原因,有针对性地提出了从工艺、材质、监管等多方面的提升来解决腐蚀问题的方案,并根据多个工程现场调整方案后的实际运行情况来对方案的可行性进行论证,基本解决了常压塔顶系统存在的腐蚀、堵塞等问题,有效延长了设备、管道使用寿命,保证了装置正常的长周期安全生产。
关 键 词:常顶挥发线;氯化氢;硫化氢;腐蚀
中图分类号:TQ 013 文献标识码: A 文章编号: 1671-0460(2020)11-2566-04
Corrosion and Blockage Principles of Atmospheric
Tower Top and Countermeasures
JIANG Lu
(PetroChina Northeast Refining Engineering Co., Ltd., Dalian 116000, China)
Abstract: Combined with the actual production situation, the specific causes of thinning, perforation, corrosion under scale, blockage and other phenomena of atmospheric tower top and cooling system in refinery atmospheric and vacuum distillation unit were analyzed, the deep causes of the corrosion and blockage were found out, and solutions to the corrosion problems were put forward from the aspects of process, material and supervision.The feasibility of the scheme was demonstrated according to the actual operation situation of several project site after using the scheme, the problems of corrosion and blockage existing in the atmospheric tower top system were basically solved, effectively prolonging the service life of equipment and pipelines, and ensuring the normal long-term safe production of the device.
Key words: Atmospheric tower top volatilization line; Hydrogen chloride; Hydrogen sulfide; Corrosion
隨着加工原油品质劣质化程度的提高和正常生产运行周期不断延长的需要,设备、管道的腐蚀问题愈发严峻[1]。在炼厂常减压装置内,常压塔顶、常顶挥发线及常顶冷却系统在运行过程中越来越多地出现以下情况:常压塔顶设备腐蚀、常顶挥发线腐蚀、常顶换热系统腐蚀、管道堵塞。常压系统的腐蚀主要集中在常压塔顶部的塔盘、塔内壁、常顶冷却系统等设备部分及常顶挥发线等管道部分,其中在塔顶油气出口附近塔壁、塔顶挥发线出口及塔顶冷却系统的换热器管壳、管束部位腐蚀最为严重。在塔顶部封头处有贴衬不锈钢的情况下腐蚀相对较轻,但在没有贴衬的地方腐蚀相对严重[2],例如塔顶挥发线出口的位置及位于贴衬不锈钢板下方的塔内壁部分。在生产运行周期内发生的腐蚀、减薄、穿孔甚至开裂,尤其在常压塔顶设备处及塔顶挥发线管道部分发生腐蚀,因设备、管道难以更换,对装置安全生产影响极大,只能在停检周期内充分论证并解决。……