摘 要:避雷器主要用于限制由线路传来的雷电过电压或由电气操作引起的操作过电压,是保证电力系统安全运行的重要保护设施之一。通过氧化锌避雷器在我矿的应用,对碳化硅避雷器和氧化锌避雷器的比较,显示了氧化锌避雷器的诸多优点,氧化锌避雷器在防雷吸收过电压方面有了质的飞跃,对电力系统的安全运行起着至关重要的作用,是防雷技术发展的必然。

关键词:防雷保护功能;操作过电压;暂态过电压;碳化硅避雷器

Abstract:Lightning arrester is mainly used to limit the lightning overvoltage from the line or the operation overvoltage caused by electrical operation. It is one of the important protection facilities to ensure the safe operation of power system. Through the application of zinc oxide arrester in cacheng coal mine,the comparison between Silicon Carbide arrester and zinc oxide arrester shows that zinc oxide arrester has many advantages,and zinc oxide arrester has a qualitative leap in lightning protection and absorbing over-voltage,it plays a vital role in the safe operation of power system and is the necessity of the development of lightning protection technology.

引言:

煤礦过去使用的过电压保护装置大多是FS阀式避雷器。避雷器主要作用,是限制由线路传来的雷电过电压或由操作过电压,保证电力系统安全运行的重要保护设备之一,其性能的好坏对保证电力系统的安全运行起着至关重要的作用。

1碳化硅避雷器和氧化锌避雷器的结构及特性

1.1 碳化硅避雷器

碳化硅避雷器的火花间隙,是由多个单向间隙串联而成,单向间隙是由上下黄铜极构成,电极中间用0.5-1mm厚的阀片隔开,压紧密封在避雷器瓷套内,阀片是由碳化硅(SiC)颗粒和水玻璃混合后,经模型压制成饼状,在低温下焙烧而成,阻值随电压的大小而变化,每个单向间隙的击穿电压为2.5-3KV。而在雷电压下电阻自动增大,限制续流在几10A内,使间隙能灭弧和断流。它只有雷电幅值(指最大幅值)限压保护功能,没有连续雷电冲击保护能力;防雷保护功能不完全,损坏爆破率高使用寿命短。

1.2 氧化锌避……