摘要:为优化配网自动化开关实用化水平,提升其在线恢复效率,文章针对人工重启终端耗时、耗力的弊端性,提出了一种新型的远程重启方案,结合所在电网公司配网自动化终端在线率现状及影响因素,着眼于重点,通过技术改造与主站建构无线网络链路通道,此实现全程无线操作,让主站基于手机设备,通过网络或短信方式便可实现对开关的远程重启操控;同时,利用联网远程遥控投退及“双确认”方法,来建构压板投退的智能化远程操控装置,以简化压板投退的操作流程、提升效率,由此,通过远程遥控器重启、保护压板投退为配网自动化开关的安全运行提供有效支撑。

关键词:配网自动化开关;远程重启;压板投退;校验装置

中图分类号:TM76;TP273

文献标识码:A

文章编号:1001-5922(2020)08-0167-04

Remote Restart of Distribution Automation Switch and PressingPlate on / off Device

LI Zheng-qiang,CHENC Zhi-qiu,PENG Yong-jian

(Foshan Sanshui Power Supply Bureau of GJuangdong Power Grid Co..Ltd..Foshan GJuangdong 528100,China)

Abstract : In order to optimize the practical level of distribution automation switch and improve its on-line recoveryefficiency,this paper proposes a new remote restart scheme for the disadvantages of manual restart terminal.which istime-consuming and labor-consuming.Combined with the status quo and influencing factors of distrihution automationterminal on-line rate of the power grid company,focusing on the key point.the wireless network link channel is con-structed through technical transformation and main station.this realizes the whole wireless operation,and enables themaster station to realize the remote restart control of the switch through the network or SMS mode hased on the mobiledevice;at the same time.the use of networked remote control for remote retre.at and - double confirmation "method to buildan intelligent remote control device for pressure plate retreat,to simplify the operation and efficiency of the pressing anddropping of the platen,and to improve the efficiency.Thus.the remote controller can restart and protect pressing plateon / off to provide effective support for the safe operation of the distribution network automation switch.

Key words : distribution network automatic switch;remote restart;pressing plate on / off;calibration device

0引言

配網自动化开关设备在配电网中发挥着可视、可测、可控的效能,为配网故障的高效定位、隔离及复电控制提供多元支撑,可降低故障停电发生率,确保用电持续、稳定性。而用电需求和质量的高标准要求下,对配网自动化开关的运维管理提出了更高的要求,据数据统计,多数地区的配网自动化开关终端在线率尚未达到95%的标准要求,实用水平不高,虽然通过终端重启可恢复大部分的在线率,但是,人工重启方式需要专业运维人员亲自前往开关站进行重启操作,耗时长、效率低,且环境因素影响下,可能无法及时退出联络点保护压板,一旦操作失误易于将瞬时故障转变为永久故障,故而,“如何保证自动化开关终端在线率,有效提高供电可靠性”是目前亟待解决的问题。……