某SUV前端模块布置选型分析与研究
2020-05-03陈帆
陈帆



摘 要:某SUV在热平衡试验中,中冷散热器出气温度超标。经排查,现有前端模块布置型式为“三明治”结构,即冷凝器—中冷散热器—散热器。由于中冷散热器布置在冷凝器后,受冷凝器出风温度高的影响,中冷出气温度难以保证。优化方案通过调整前端模块布置型式,然后使用一维和三维软件联合仿真,验证优化方案可使中冷出气温度降低。
关键词:前端模块;中冷散热器;出气温度高;联合仿真
Abstract: In the heat balance test of an SUV, the outlet temperature of intercooler radiator exceeded the standard. According to the investigation, layout form of the existing FEM is "sandwich" structure,that means condenser-intercooler radiator- radiator. Since the intercooler is arranged behind the condenser, it is difficult to guarantee the air temperature of intercooler due to the high temperature of the condenser. By adjusting the layout of FEM, and then using the joint simulation of 1d and 3d software, the optimization scheme is verified to reduce the temperature of the outlet gas.
引言
熱平衡性能作为整车性能开发的一项关键指标,对整车动力性、经济性能否达标起重要作用。影响热平衡性能的主要因素有散热器和风扇性能、进风面积、前端模块的布置。本文利用flowmaster和star-ccm+联合仿真,分析并优化某车前端模块的布置,最终解决热平衡性能不足的问题。
1 现有方案介绍
本文中SUV前端模块布置,目前采用“三明治”结构,即从进气格栅开始,按冷凝器-中冷散热器-散热器-风扇顺序排列,四者Z向高度基本一致。“三明治结构”如图1示。
在某次热平衡试验中,采集到的中冷散热器出气温度高,超出设计目标值,需做优化调整。试验结果如表1示。
2 优化方案说明
针对该SUV中冷出气温度超标问题,通过排查中冷散热器性能、风扇性能和前端模块布置,最终选择优化前端模块的布置型式。优化后前端模块布置如图2示。
优化方案将中冷散热器布置在冷凝器下端(简称上下式),一方面避免了冷凝器后出风温度高的影响,另一方面中冷器可以直接吹到环境风,有利于降低出气温度。……