APP下载

Reconstruction of Paprosky type lllB acetabular bone defects using a cup-on-cup technique:A surgical technique and case series

2020-04-23YinQiaoDuYuPingLiuJingYangSunMingNiYongGangZhou

World Journal of Clinical Cases 2020年7期
关键词:误码率接收端光纤

Yin-Qiao Du,Yu-Ping Liu,Jing-Yang Sun,Ming Ni,Yong-Gang Zhou

Yin-Qiao Du,Jing-Yang Sun,Ming Ni,Yong-Gang Zhou,Department of Orthopedics,Chinese People's Liberation Army General Hospital,Beijing 100853,China

Yu-Ping Liu,Department of Orthopedics,Tengzhou Central People's Hospital,Tengzhou 277500,Shandong Province,China

Abstract

Key words: Total hip arthroplasty;Trabecular metal;Cup-on-cup;Bone defect

INTRODUCTION

Acetabular bone defects are becoming more common in revision total hip arthroplasty(THA).The reconstruction of the defects may be a surgical challenge.Several classification systems have described acetabular bone defects,but the most helpful for developing surgical strategies is the Paprosky classification[1,2].Paprosky type IIIB defects are defined as “up and out” defects with more than 60% of the acetabular rim compromised and superomedial migration of femoral head greater than 3 cm[1].

For the reconstruction of the defects,structural allograft has been used to initially stabilise the cementless hemispherical acetabular component in the past decades[3,4].However,due to the collapse,resorption,nonunion,loosening,and infection of the grafts,the cementless acetabular component that lacked successful biological fixation and bone graft incorporation became susceptible to loosening.The success rate of structural allografts was approximately 65% in a series of systematic reviews of the literature[3-7].The common causes of failures were as described above[3,6,7].

To solve the above problems,“nonresorptive structural allografts”,namely,trabecular metal (Zimmer,Warsaw,IN) augments,have been widely used during the past decade[8-12].With high frictional characteristics,low modulus of elasticity,and high volumetric porosity (70% to 80%),the acetabular component and augment posses high bone ingrowth potential and can obtain long-term biological fixation[12-14].Therefore,multiple sizes and shapes of the acetabular augments have emerged to adapt and reconstruct various acetabular bone defects.Hemispheric acetabular components with trabecular metal augments have been reported by many authors to be associated with excellent clinical results,such as acceptable postoperative hip function,low rates of aseptic loosening and other complications during mean followup periods ranging from 37 to 60 mo[9-11].

Many surgeons have utilized two trabecular metal augments to reconstruct the superomedial type IIIB defects.However,the two largest trabecular metal augments cannot reconstruct the defects or restore the normal hip centre of rotation (COR)because the defects are too large.For the sake of solving the problem,we utilized a cup-on-cup technique to reconstruct the Paprosky type IIIB acetabulum bone defects and restore the normal hip COR.We defined the tantalum metal (TM) revision shell that was removed from the peripheral titanium ring as a TM-cup augment and the cementless hemispherical acetabulum component combined with a TM-cup augment as the cup-on-cup technique.

The purpose of this study was to report the short-term results of patients with type IIIB acetabulum bone defects reconstructed using our cup-on-cup technique.

MATERIALS AND METHODS

We retrospectively reviewed six patients (six hips) who underwent acetabular reconstruction for Paprosky type IIIB acetabular bone defects using our cup-on-cup technique from January 2015 to January 2017 (Table 1).There were four females and two males with a mean age of 59 years (range from 29 to 73 years).The causes of revision surgery were aseptic loosening in five hips and a primary THA with severe defects because of posttraumatic acetabular comminuted fracture and infection in one hip.None of the participants had pelvic discontinuity.All patients were followed clinically and radiographically for a mean duration of 42 mo (range,36 to 52 mo).No patients were reported as lost to either clinical or radiographic follow-up.

Surgical technique

All surgeries were performed by one author (Zhou YG) at the General Hospital of the Chinese People's Liberation Army (Beijing,China).The classification of these defects was based on pre-operative standard radiographs and computed tomography of the acetabulum and intra-operative assessment according to the Paprosky classification[1].A standard posterior-lateral approach was used for each case.Extended trochanteric osteotomies (ETOs) were performed in two hips to remove the failed components,improve exposure,and assist in the balancing of soft tissue.Acetabular reconstruction began by removing the failed acetabular components,bone cement,and any fibrenecrotic tissue.The superomedial defects in conformity with Paprosky type IIIB were detected in six hips.Conventional hemispherical reamers of different diameters were used to detect the defects' shape and size;the latter were constrained by the anterior and posterior acetabular walls.Then,a TM revision shell removed from the peripheral titanium ring (TM-cup augment) was inserted into the shaped defects,and the TM-cup augment with pressfit was stabilised and secured against the host bone with the screws that were placed according to the bone mass around the acetabulum.Next,hemispherical reamers of different diameters were used again to shape the acetabulum by reaming the bone at the periphery of the acetabulum and the periphery of the TM-cup augment rim.Until the size of the reamer was constrained by the acetabular walls and the augment or a stable 3-point fixation was achieved by the ischium and the augment[15],a cementless hemispherical acetabulum component (a Pinnacle or trabecular metal revision component) was inserted.The cement was only placed between the TM-cup augment and the hemispherical acetabulum component,and the rest of the surface of the cementless acetabular component was covered with the host acetabular bone (Figure 1).Additional screws were inserted into the acetabular bone through the holes in the acetabular component to enhance the initial stability.In four of the six cases,additional screws were inserted though both the acetabular component and the TM-cup augment into the ilium to further enhance fixation.To do this,we needed to create additional screw holes in the TM revision shell or the TM-cup augment with a high-speed burr.

The mean diameter of the TM-cup augment was approximately 50 mm (range from 48 to 52 mm).The Pinnacle acetabular cup was used in three hips,and the TM revision shell was used another three hips.The mean diameter of the Pinnacle acetabular cup was approximately 57 mm (range from 54 to 60 mm),and the TM revision shell was approximately 57 mm (range from 56 to 58 mm).A mean of four bone screws (range from 3 to 5) were used for each acetabular reconstruction,with a median of two screws inserted through the acetabular component (range from 1 to 3)and a median of two screws inserted through the TM-cup augment (range from 1 to 3).

Once the acetabular component and augment were secured,a liner was implanted into the acetabular component.A highly cross-linked polyethylene liner was used in five hips,and a ceramic liner was used in one hip.The femoral head size was 32 mm in one hip and 36 mm in five hips (Table 2).

Postoperative recovery included partial weight bearing with the use of crutches for the first six weeks.Full weight bearing was allowed thereafter.The patients stayed in the hospital for a mean of 8.7 d (range from 7 to 10 d).

Clinical and radiographic assessment

Clinical and radiological evaluations were performed pre-operatively;at 3 mo,6 mo,and 1 year postoperatively;and annually thereafter.The functional results of the arthroplasty were recorded according to the Harris hip score[16].A case was considered a clinical failure if the component was revised again or if the clinical score was worse than the pre-operative score.

Standard radiological analysis was performed on serial anteroposterior radiographs of the pelvis and lateral views of the operated hip.The vertical position of the hip COR was measured from the inter-tear drop line to the centre of the femoralhead,and the horizontal position was measured between the femoral head centre and the perpendicular line from the inter-tear drop line at the tear drop[17].

Table1 Patients’ demographic data

The presence and evolution of radiolucent lines in the three zones of DeLeeet al[18]were recorded.The component was considered unstable if a radiolucent line at least 1 mm wide crossed all three acetabular zones or if any component migration could be found.The fibrous stability of the component was characterized by a radiolucent line less than 1 mm wide that crossed two of the three zones,while the component was considered stable with the presence of bone ingrowth if the component was in close contact with the pelvic bone and no radiolucent lines were found in at least two of the three zones[19].Radiologically,a change in the abduction angle of the acetabular component of more than 10° or a change in the vertical or horizontal position of the component > 6 mm were defined as loosening[9].The presence of osseointegration was evaluated according to the Moore criteria[20].Five radiographic signs were used:Absence of radiolucent lines,presence of superolateral support,medial stressshielding,radial trabeculae,and inferomedial support.When three or more signs were present,the positive predictive value of the radiographic test was 96.9%,the sensitivity was 89.6%,and the specificity was 76.9%.

别人的婚姻是爱情的尘埃落定,他们的婚姻,却是一场隐形战争的开始,是她对他爱的争夺战。在这场战争里,丁小慧一刻都不曾放松。

The Ethics Committee of the General Hospital of Chinese People's Liberation Army approved the study protocol.All study participants provided written informed consent for the study.

RESULTS

The mean Harris hip score improved from 32.4 ± 10.1 (range from 19.8 to 50.2) preoperatively to 80.7 ± 5.6 (range from 71.5 to 87.5) at the last follow-up.Pre-operatively,five patients had severe pain,and one had moderate pain.At the last follow-up,four patients had no pain,and two had slight pain.Pre-operatively,three patients needed a cane for long walks and three needed full-time support with crutches.At the last follow-up,all six patients could walk unaided.Pre-operatively,five patients had a severe limp,and one had a moderate limp.At the last follow-up,five patients had no limp and one had a moderate limp.

在实际应用中,由于光学装调误差、环境温度、发射和接收平台振动等会引入光纤对准误差和光束随机抖动误差,致使模场匹配程度下降,耦合效率降低,从而导致接收端信噪比下降,误码率提高,通信质量变差.接下来将推导并建立不同影响因素下空间光-少模光纤耦合效率的数理模型.

The mean vertical position of the hip COR from the inter-teardrop line changed from 60.9 ± 7.5 mm (range from 50.8 to 70.2 mm) pre-operatively to 31.7 ± 8.8 mm(range from 25.2 to 49.3 mm) postoperatively.Postoperatively,the vertical position of five patients was less than 35.0 mm and that of one was 49.3 mm.The mean horizontal position of the COR from the teardrop changed from 33.6 ± 5.0 mm (range from 28.5 to 39.5 mm) pre-operatively to 38.9 ± 5.0 mm (range from 32.7 to 47.8 mm)postoperatively.

At the last follow-up,there was no evidence of component migration compared to the initial postoperative views.A radiolucent line was noted in one of the six hips,and in this case,there was a radiolucent line smaller than 1 mm seen in zone C 3 mo after surgery.However,the radiolucent line remained stable,and no further progression was noted at the last follow-up.All the acetabular domes presented at least three or more signs of fixation,in accordance with the criteria of Moore (Figure 2).

Figure1 The surgical technique.

Complications

Greater trochanteric migration after ETO occurred in one of six hips at 3 mo.The patient had a moderate limp,but she was quite satisfied with the current condition and did not expect for a surgery to fix the migrated greater trochanter.

There were no cases of deep infection,deep venous thrombosis,nerve injuries,pulmonary embolism,or death as a result of the revision procedure.

DISCUSSION

Management of Paprosky type IIIB acetabulum bone defects is a challenging and unique reconstructive procedure.Superomedial defects are very common in revision THA.To address this problem,we used our own cup-on-cup technique with a cementless hemispherical acetabulum component and a tantalum metal revision shell as a TM-cup augment.The TM-cup augment was implanted to reconstruct the superomedial defects,and then the hemispherical acetabulum component was implanted into the reconstructed acetabulum.

The TM augment was first introduced in 1997 and possesses a high coefficient of friction and porosity[14].Moreover,TM offers good bioactive and biological bonds to host bone,and its characteristics include a high volumetric porosity,which appears optimal for bone ingrowth,and a roughened surface micro-texture that provides a scratch fit for increased initial stability upon implantation[21].All the above properties of TM are why it is increasingly used in revision THA with severe acetabular bone defects.Recently,many short-term reports have shown encouraging results from using TM augments in type III acetabular defects (Table 3).Del Gaizoet al[10]reported that only one of 37 hips (2.7%) failed as a result of aseptic loosening during a mean follow-up period of 60 mo (range from 26 to 106 mo).Grappioloet al[11]reviewed 55 acetabular revisions with a mean follow-up period of 53.7 mo (range from 36 to 91 mo) and reported three cases of revision for aseptic loosening (5.5%).Lingarajet al[8]and Sporeret al[9]reported no aseptic loosening in their studies.Moreover,recurrent instability was very common in revisions[8-11].

In our practice,we strived to restore the anatomical position of the hip COR to achieve effective functioning of the abductors.During the surgical procedure,in the presence of severe superior and medial migration of the hip COR,we utilized the TMcup augment to reconstruct the superomedial defects and restored the normal position of the hip COR.The level of the hip COR was normal in five patients;we could not restore a normal hip COR in one patient due to the large superior defects.Finally,despite the large and severe size of the defects,we were able to use a medium cup size in all patients.Avoiding using jumbo-cup could also prevent impingement between the acetabular construction and soft tissue around the hip[22].

Table2 lmplants used

Shethet al[23]and Paproskyet al[1]recommended removing the peripheral titanium ring to facilitate the placement of screw holes at the periphery of a TM revision shell and gained screw access to the ischium and/or superior public ramus.We regarded the TM revision shell with a removed peripheral titanium ring as a TM-cup augment.We utilized the TM-cup augment to reconstruct the large type IIIB superomedial defects and made additional screw holes in it with a high-speed burr.Blumenfeldet al[24]described a cup-in-cup technique in which a large tantalum acetabular shell was placed onto supportive host bone in a cementless fashion and a smaller shell was cemented into the larger one,using the technique to restore offset in severe acetabular defects[24].There was no evidence of loosening or migration during an average followup period of 28 mo (range from 12 to 50 mo).Based on the aforementioned report,we developed our cup-on-cup technique to reconstruct the type IIIB acetabulum bone defects.A smaller cup rode on the superomedial region of a larger one,instead of smaller cup,was implanted into the larger one (cup-in-cup technique).The larger cup was put into the true acetabular region,which make it possible that the large head was used in the revision THA.

The cup-on-cup technique achieved better clinical results in our study,but two concerns existed with this technique.One was the TM particulates that were caused by reaming the TM-cup augment rim,which may have an effect on the friction interface and may result in the increasing wear of the highly cross-linked polyethylene liner.During the surgical procedure,we used copious physiological sodium chloride solution to repeatedly wash off the particulates to minimize the damage.The other concern was the durability of the cementation between the augment and the acetabular component.We used a screw to fix the augment and acetabular component by making additional screw holes in the acetabular component or the TM-cup augment,which may prevent the failure of the cementation.

Additionally,cost may be a factor in the reconstruction of severe bone defects.The cost of the cup-on-cup technique was lower than that of using two conventional TM augments to reconstruct severe superomedial defects in China.

We acknowledge the limitations of our study.The first limitation is the retrospective design.Ideally,a randomized controlled trial should be performed comparing this type of reconstruction with other techniques,such as a structural allograft.Second,there was a very small number of patients in our study.Third,the follow-up duration was short,and further results are unknown.

In conclusion,we judge our cup-on-cup technique to be an excellent choice to reconstruct severe superomedial defects and restore the level of the normal hip center of rotation.We will continue to use the technique and follow the patients to obtain long-term clinical results.

Table3 Comparison of studies reporting reconstructions for Paprosky type lll acetabulum bone defects with tantalum metal augments

Figure2 A 29-year-old man with posttraumatic acetabular defect and recurrent infection.

ARTICLE HIGHLIGHTS

Research background

Acetabular bone defects are becoming more common in revision total hip arthroplasty.The reconstruction of the defects may be a surgical challenge.For the reconstruction of the defects,structural allograft has been used to initially stabilise the cementless hemispherical acetabular component in the past decades.However,due to the collapse,resorption,nonunion,loosening,and infection of the grafts,the cementless acetabular component that lacked successful biological fixation and bone graft incorporation became susceptible to loosening.The success rate of structural allografts was approximately 65% in a series of systematic reviews of the literature.

Research motivation

Trabecular metal with high frictional characteristics,low modulus of elasticity,and high volumetric porosity (70% to 80%) has been widely used to reconstruct the defects during the past decade.Hemispheric acetabular components with trabecular metal augments have been reported by many authors to be associated with excellent clinical results.Many surgeons have utilized two trabecular metal augments to reconstruct the superomedial type IIIB defects.However,the two largest trabecular metal augments cannot reconstruct the defects or restore the normal hip centre of rotation because the defects are too large.For the sake of solving the problem,we utilized a cup-on-cup technique to reconstruct the Paprosky type IIIB acetabulum bone defects and restore the normal hip centre of rotation.

Research objectives

The main objective of this study was to report the short-term results of patients with Paprosky type IIIB acetabular bone defects reconstructed using the cup-on-cup technique.

Research methods

Six patients (six hips) with a mean age of 59 years who underwent acetabular reconstruction using our cup-on-cup technique between January 2015 and January 2017 were retrospectively reviewed.All patients were followed both clinically and radiographically.

Research results

The mean Harris hip score improved from 32.4 pre-operatively to 80.7 at the last follow-up.Greater trochanteric migration after extended trochanteric osteotomy occurred in one of six hips at 3 mo.There was no evidence of component migration at the last follow-up.

Research conclusions

We present the clinical and radiographical results of six patients with type IIIB acetabular bone defects.The short-term results suggest that our cup-on-cup technique could be considered an effective management option for Paprosky type IIIB acetabular bone defects without pelvic discontinuity.

Research perspectives

Due to the retrospective nature of this study and the small sample,it is difficult to obtain reliable conclusions.However,our study provides a new surgical technique to reconstruct the Paprosky type IIIB acetabulum bone defects.

猜你喜欢

误码率接收端光纤
基于扰动观察法的光通信接收端优化策略
面向通信系统的误码率计算方法
FIBBR King-A系列HDMI光纤线
纯多播BC 信道并存单播MAC 信道的天线效率研究
手机无线充电收发设计
一种快速同步统计高阶调制下PN 码误码率的方法∗
高品质的忠实还原 FIBBR Ultra Pro2 HDMI光纤线
一条光纤HDMI线的诞生长飞/长芯盛FIBBR工厂走访实录
光纤与光纤传感器
失效网络中节点可通信性能评估方法研究