浅谈循环流化床锅炉返料送风机运行优化自动控制

2020-04-09马新华

价值工程 2020年6期
关键词:变频器控制策略优化

马新华

摘要:针对循环硫化床锅炉返料风机中断事故,从热控自动化DCS优化控制策略出发,通过分析事故原因着手,分析设备结构、电气特性,发掘改造DCS控制策略,弥补减小事故发生,改善循环硫化床锅炉的安全运行。

Abstract: In view of the interruption of the return air of the circulating sulfurized bed boiler, this paper starts from the thermal control automation DCS optimization control strategy, analyzes the cause of the accident, the equipment structure and electrical characteristics, to explore and reform the DCS control strategy to make up for and reduce the occurrence of the accident, so as to improve the safe operation of circulating sulfurized bed boiler.

关键词:循环硫化床锅炉返料风机重要性;设备结构;电气特性;控制策略优化;减小事故发生及扩大

Key words: importance of recirculation fan of circulating fluidized bed boiler;equipment structure;electrical characteristics;control strategy optimization;reducing accident occurrence and expansion

中圖分类号:U231.3                                     文献标识码:A                                  文章编号:1006-4311(2020)06-0158-02

0  引言

锅炉热控设计是一个重要的的过程,尤其是在循环流化床中由于锅炉燃烧及受热的动态积蓄效应导致高温灰分及残炭的循环效率直接影响温度分布的变化,只要保证硫化风的硫化作用,瞬间的燃料中断也不会影响锅炉炉膛灭火,所以炉膛结焦与灭火相对而言,结焦摆放在了第一位。

影响CFB(Circulating fluidized bed,是指循环流化床)锅炉结焦的因素一般有:①燃料的影响;②运行参数的影响;③返料的影响;④设备结构的影响;⑤运行人员操作的影响。

由于返料故障引起的结焦造成的高温结焦,如果处理不及时渣块在床料中存在并随着时间的推移,焦块将越来越大,造成流化困难,堵塞排渣管,最后被迫停炉。

新疆骑马山热力有限公司属于孤网运行系统由于多起返料风中断引起的事故,给我公司安全生产造成了重大损失,分析设备存在的隐患后改造优化并取得良好效果。

1  设备结构

①新疆骑马山热力有限公司目前有2台65T/H循环流化床锅炉,该炉型具有双分离器、双返料器,且左右并列布置于炉膛和尾部竖直对流烟道中间。……